3-100
One-byte messages consist of a single byte transferred during a
MESSAGE phase. The value of the byte determines which message is
to be performed as defined in Table 3.83 (See ANSI SCSI-2 6.6
Table 10). The implemented Message Codes by this scanner is Table
3.83.
Table 3.83 Message Codes
Code
Support Message Name
Init
Targ
00h
M
M
COMMAND COMPLETE
02h
O
O
SAVE DATA POINTER
03h
O
O
RESTORE POINTERS
04h
O
O
DISCONNECT
05h
M
M
INITIATOR DETECTED
ERROR
06h
O
M
ABORT
07h
M
M
MESSAGE REJECT
08h
M
M
NO OPERATION
09h
M
M
MESSAGE PARITY ERROR
0Ch
O
M
BUS DEVICE RESET
80h+
M
O
IDENTIFY
80h+
M
M
IDENTIFY
***
O
O
SYNCHRONOUS DATA
TRANSFER REQUEST
others
Reserved
Key:
M: Mandatory support, O = Optional support
In: Target to initiator, out = Initiator to target.
Yes: Initiator shall negate ATN before last ACK of message.
No: Initiator may or may not negate ATN before last ACK of
message. (see Attention Condition)
—: Not Applicable
***: Extended message (see Tables 3.84 and 3.85)
80h: Codes 80h through FFh are used for IDENTIFY messages.
(See Table 3.86).
Direction
Nefate ATN
Before last
ACK
In
In
In
In
Out
Yes
Out
Yes
In
Out
Yes
Out
Yes
Out
Yes
Out
Yes
In
Out
No
In
Out
Yes