Page Code:
The Page Code fields identifies the format and parameters defined
for that mode page.
This scanner supports 3Dh(Lamp Timer), 3Eh(Job Separation
Sheet).
The page length field specifies the length in bytes of the mode
parameters that follow. If the initiator does not set this value to the
value that is returned for the page by the MODE SENSE command,
the target shall terminate the command with CHECK
CONDITION status. The sense key shall be set to ILLEGAL
REQUEST with the additional sense code set to INVALID FIELD
IN PARAMETER LIST. The target is permitted to implement a
mode page that is less than the full page length defined by this
standard provided no field is truncated and the page length field
correctly specifies the actual length implemented.
(a) Lamp Timer page
The Lamp Timer page provides to adjust the Turn-Off time of
fluorescent lamp.
Table 3.72 Lamp Timer page
Bit
7
6
Byte
0
Reserved
1
2
3
7
Lamp Timer:
This field specifies the fluorescent lamp turn off time in second after
scanning. 0 specifies default time(60 seconds). 1 through 255
seconds can be specified.
3Dh(Lamp Timer), 3Eh(Job Separation
Sheet)
5
4
3
Page Code (3Dh)
Page Length (06h)
Lamp Timer
Reserved
0 to 255 (second)