Registry Setting - Fujitsu PRIMERGY 4Gbit/s FC I/O Modules Owner's Manual

Primergy 4gbit/s fc i/o modules
Table of Contents

Advertisement

5.2

Registry Setting

1
Click the "Start" button
2
Enter a name in "Name" as follows, and click [OK].
regedit
The registry editor starts.
3
Follow the paths below.
\HKEY_LOCAL_MACHINE
\SYSTEM
\CurrentControlSet
\Services
4
Check that the key name "TimeOutValue" values have the relations
described in the table below.
If there is no value in the "TimeOutValue", add it as follows:
- Data type
- The name of the value
- The data of the value
- Base
Table: values in the "TimeOutValue"
Product names
Windows Server 2003
5
After finishing all the settings, restart the server blade.
After configuring the cluster, recheck these settings. If the settings are incorrect,
perform the setting again.
"Run..." in this order.
\Disk
: REG_DWORD (DWORD type)
: TimeOutValue
: (Refer to the following table)
: Hexadecimal
Connection configuration
Single connection
3c (hexadecimal)
Cluster configuration
3c (hexadecimal)
5 4Gbit/s FC I/O Module Details Setting
E
71