Fujitsu PRIMERGY 4Gbit/s FC I/O Modules Owner's Manual page 31

Primergy 4gbit/s fc i/o modules
Table of Contents

Advertisement

• When selected the adapter to be set and "Driver Parameters" (Individual setting for each
adapter)
In the above diagram, "BX620 S3" represents a local server, and "BX600-FC42E -
10:00:00:00:C9:48:FE:0C" represents an installed 4Gbit/s FC I/O Module.
3
Click [Topology] in "Adapter Parameter".
4
Select a value representing the connection type from the list box
to "Value" in "Modify Adapter Parameter", and click [Apply].
Connection type
FC-AL
Fabric
5
Click [QueueDepth] in "Adapter Parameters".
6
Set a value in "Value" in "Modify Adapter Parameter", and click
[Apply].
The setting value is calculated as follows:
For ETERNUS3000 model 50/GR710/GR720/GR730/GR740/GR820/GR840
• For cluster (MSCS/SynfinityCluster): "8"
• For other than cluster (MSCS/SynfinityCluster)
• When one HBA is connected to one FC-CA (FC port): "16"
• When two HBAs are connected to one FC-CA (FC port): "8"
For ETERNUS3000 model 80/100/200/300/400/500/600/700 and
ETERNUS4000 model 80/100
Setting value (rounding down decimals) = 40/ (number of 4Gbit/s FC I/O Module connected
When the calculated value is 8 or less, specify "8".
For ETERNUS6000 model 400/500/600/700/800/900/1000/1100
Specify "40".
Value
0
1
to one CA port)
5 4Gbit/s FC I/O Module Details Setting
E
69

Advertisement

Table of Contents
loading

This manual is also suitable for:

Primergy pg-fcd201