Esf Solutions Backup - Lexmark C950 Service Manual

Service manual
Hide thumbs Also See for C950:
Table of Contents

Advertisement

5058-030
Remove the RIP PCBA.
2.

eSF solutions backup

If a technician needs to replace the RIP PCBA, the steps below should be taken to back up the eSF solutions
and settings:
POR the printer into invalid engine code mode.
1.
2.
Open a Web browser and navigate to the printer's Web page.
Navigate to Settings, and click the link.
3.
4.
Navigate to Solutions and click the link.
Navigate to Embedded Solutions and click the link.
5.
On the Embedded Solutions page, select the apps to be exported by clicking the selection box next to the
6.
app.
7.
Choose Export.
If the Web page cannot be accessed, or an error persists despite trying to boot in Invalid Engine code mode,
then there is no way to backup the eSF apps. The technician needs to make the customer aware that the
applications and their setting could not be saved.
Note: There is a size limit on the export file - 128kb. Because of this, it is recommended that you don't use
the "global" backup found in Settings --> Import/Export --> Export Shortcuts File, Export Settings File,
Export Embedded Solutions Settings File and Export Security Setups File. Customers with a large
Service Manual
4-146
Previous
Next
Go Back

Advertisement

Table of Contents
loading

Table of Contents