Chapter 3 ________________________________________________________________ Operation
VAISALA _______________________________________________________________________ 37
3.
Place the battery in a water container with the connectors facing
upwards and immerse in water for four minutes. Use fresh tap
water, with a temperature of 15...25 °C.
Figure 29
Battery Immersed in Water
0705-040
4.
Take the battery out of the water after four minutes of immersion.
Do not squeeze water out of the battery.
5.
Put the battery back into the case. Note that one end of the battery
is waxed to prevent leakage, see the circle in
Place the battery so that the waxed end points to the small
projections on the case.
Figure 30
Battery in the Case, Waxed End Circled
0705-041
Figure 30 on page
37.