Worldwide QuickSpecs — Version 11 — 11.16.2009
1.70 x 17.64 x 26.85 in (4.32 x 44.80 x 68.20 cm)
Maximum
(all hard drives, power
supplies, and processors
installed)
Minimum
(one hard drive, power
supply, and processor
installed)
Rated Line Voltage
Rated Input Current
Rated Input Frequency
Rated Input Power
Maximum
To review typical system power ratings use the Power Advisor which is
available via the online tool located at URL:
www.hp.com/go/proliant-energy-efficient
Or
www.hp.com/go/hppoweradvisor
- Click on the system of interest. Example: DL160 G6
- Follow the instructions of the next screens.
Rated Steady-State Power 500 Watts (at 100 VAC),
Maximum Peak Power
(See Power Specifications
Tables)
HP ProLiant DL160 Generation 6
34.00 lb (16.78 kg)
28.00 lb (12.7 kg)
90 to 132 VAC
180 to 264 VAC
5. 8 Amps (at 100 VAC) to 2.9 Amps (at 200
VAC)
47 to 63 Hz
570W (at 100 VAC)
565W (at 200 VAC)
500W
1940 BTU / hr (at 100
VAC)
1920 BTU/hr (at 200
VAC)
460W
1773 BTU / hr (at 120
VAC)
1715 (at 240 VAC)
750W
2892 BTU / hr (at 120
VAC)
2797 (at 240 VAC)
500 Watts (at 200 VAC)
500Watts (at 100 VAC),
500 Watts (at 200 VAC)
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.