Relative Humidity; Acoustic Noise - HP ProLiant DL160 Generation 6 Specification

Hide thumbs Also See for ProLiant DL160 Generation 6:
Table of Contents

Advertisement

QuickSpecs
Technical Specifications

Relative Humidity

(non-condensing)
Altitude

Acoustic Noise

Emissions Classification
(EMC)
DA - 13247
Worldwide QuickSpecs — Version 11 — 11.16.2009
Non-operating
Operating
Non-operating
Operating
Non-operating
Listed are the declared A-Weighted sound power levels (LWAd) and
declared average bystander position A-Weighted sound pressure levels
(LpAm) when the product is operating in a 23°C ambient environment. Noise
emissions were measured in accordance with ISO 7779 (ECMA 74) and
declared in accordance with ISO 9296 (ECMA 109).
Idle
LWAd
LpAm
Operating
LWAd
LpAm
FCC Rating
Normative Standards
NOTE: Product conformance to cited product specifications is based on
sample (type) testing, evaluation, or assessment. This product or family of
products is eligible to bear the appropriate compliance logos and statements.
HP ProLiant DL160 Generation 6
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-condensing.
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
3050 m (10,000 ft). This value may be limited
by the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500
ft/min).
6.3B
48dBA
6.3B
48dBA
Class A
CISPR 22; EN55022; EN55024; FCC CFR 47,
Pt 15; ICES-003; CNS13438; GB9254;
K22;K24; EN 61000-3-2; EN 61000-3-3; EN
60950-1; IEC 60950-1
Page 48