Environmental and technical specifications
There are specific environmental and technical specifications for each hardare platform. The
specifications help you when planning the appropriate installation location, environmental conditions, and
resources, such as power and cooling.
Enclosure size and weights
OmniCube servers have specific size dimensions and weights. This information helps you when planning
to install the enclosure in a rack.
Dimension
Enclosure width
Maximum height
Maximum depth (from rack
flange)
The maximum weight of a system with all storage drives installed is 30.4 kg, or 67.02 lbs.
Power and thermal
OmniCube servers have two redundant power supplies with specific power and thermal specifications.
Table 5: OmniCube Power and Thermal Specifications
Specification
Current consumption
Supply voltage
Frequency
Heat dissipation
Maximum inrush current
Energy efficiency
Power supply efficiency
Temperature and humidity
OmniCube servers have limits for temperature and humidity under operating and storage conditions.
14
Environmental and technical specifications
Centimeters
48.2
8.73
75.58
Description
10A-5A
100–240V AC (autoranging). Make sure each
power source has sufficient electrical overload
protection.
50/60Hz
4100 BTU/hr max
55A
Energy Star, spec version 1.0
90-96% efficient (load dependent)
Inches
17.5
3.44
29.75