Download Print this page

Technical Specifications - HP ProLiant BL465c Generation 7 (G7) Quickspecs

Hide thumbs Also See for ProLiant BL465c Generation 7 (G7):

Advertisement

QuickSpecs

Technical Specifications

System Unit
System Unit
System Unit
System Unit
Dimensions
Dimensions
Dimensions
Dimensions
(H x W x D)
Weight
Weight
Weight
Weight
(approximate)
Power Specifications
Power Specifications
Power Specifications
Power Specifications
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature Operating
System Inlet Temperature
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
Altitude
Altitude
Altitude
Altitude
Acoustic Noise
Acoustic Noise
Acoustic Noise
Acoustic Noise
DA - 13654
Worldwide — Version 3 — June 24, 2010
HP ProLiant BL465c Generation 7 (G7) Server Blade
HP ProLiant BL465c Generation 7 (G7) Server Blade
HP ProLiant BL465c Generation 7 (G7) Server Blade
HP ProLiant BL465c Generation 7 (G7) Server Blade
7.154 x 2.19 x 20.058 in (18.17 x 5.56 x 50.95 cm)
Maximum
(all hard drives, DIMMs,
and processors installed)
Minimum
(no hard drives, two
DIMMs, and one
processor installed)
For power specifications including Input Requirements, BTU Rating, and
Power Supply Output, please see the HP BladeSystem c-Class Enclosures
QuickSpecs located at URL:
HP BladeSystem c3000 Enclosure QuickSpecs:
http://h18000.www1.hp.com/products/quickspecs/12790_div/
12790_div.html
HP BladeSystem c7000 Enclosure QuickSpecs:
http://h18000.www1.hp.com/products/quickspecs/12810_div/
12810_div.html
To review typical system power ratings use the HP BladeSystem Power Sizer
which is available via the online tool located at URL:
http://www.hp.com/go/bladesystem/powercalculator
NOTE:
NOTE:
NOTE: For optimal cooling and system performance the BL465c G7
NOTE:
requires the c7000 enclosure to be configured with 10 fans and the c3000
enclosure to be configured with 6 fans.
Non-operating
Operating
Non-operating
Operating
Non-operating
For acoustic noise specifications, please see the HP BladeSystem c-Class
Enclosures QuickSpecs located at URL:
13.9 lb (6.3 kg)
9.8 lb (4.45 kg)
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed. System performance may be reduced if
operating with a fan fault, or above 30°C (86°F).
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.
3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).