HP ProLiant DL160 Generation 6 Specification page 8

Hide thumbs Also See for ProLiant DL160 Generation 6:
Table of Contents

Advertisement

QuickSpecs
Standard Features
Industry Standard
Compliance
Security
Security - Trusted Platform
Module
Server Power Cords
UPS and PDU Power
Cord Matrix
ACPI V2.0 Compliant
PCI 2.2 Compliant
PXE Support
WOL Support
Microsoft® Logo certifications
IPMI 2.0, SMASH CLP compliant
Power-on password
Setup password
Diskette boot control
Secure Sockets Layer (SSL)
Secure Shell (SSH)
The TPM (Trusted Platform Module) is a microcontroller chip that can securely store artifacts used to
authenticate the server platform. These artifacts can include passwords, certificates and encryption keys.
Windows® BitLocker™ Drive Encryption (BitLocker) is a data protection feature available in Windows
Server® 2008. BitLocker leverages the enhanced security capabilities of a Trusted Platform Module (TPM)
version 1.2. The TPM works with BitLocker to help protect user data and to ensure that a server running
Windows Server 2008 has not been tampered with while the system was offline.
NOTE: For more information about TPM, including a white paper, go to:
NOTE: ProLiant OS pre-installed units will come with the partition required for TPM deployment.
NOTE: The TPM key is unique to every TPM deployed server and must be retained. Misplacing or losing
the key could result in data loss.
One 6' Highline (IEC-IEC) power cord ships standard
NOTE: HP ProLiant DL servers no longer ship standard with NEMA power cords (163719-002) that
allow connection to 110V US wall outlets in a home or office. ProLiant DL servers are primarily connected
to PDU's in data center racks so they now ship standard with only a PDU power cord (416151-B21). If a
user wishes to power a ProLiant DL server using a 110V receptacle (NEMA-15), the NEMA power cord
(227099-001) must be ordered separately.
If customers require a local power cord, they can check the power cord matrix for the appropriate cord.
Please see the following power cord matrix: http://www.hp.com/go/powercordmatrix.
Please see the UPS and PDU cable matrix's on the HP Power Protection and Management page. Under
Power Cords, click on the "HP Power Cord Matrix" link. That link will list cable descriptions, requirements,
and specifications for UPS and PDU units. Please see the following link:
www.hp.com/products/powercords.
DA - 13247
Worldwide QuickSpecs — Version 11 — 11.16.2009
intended for heterogeneous environments deploying Windows, Linux,
VMware ESX and Microsoft Hyper-V systems.
Insight Control server deployment includes one year of 24 x 7 HP Software
Technical Support and Update Service ensuring rapid access to HP support
staff and proactive delivery of software updates. For more information about
this service, please visit: http://www.hp.com/services/insight.
HP ProLiant DL160 Generation 6
http://www.hp.com/go/TPM
Page 8

Advertisement

Table of Contents
loading

Table of Contents