Technical Specifications - HP ProLiant BL490c Generation 7 (G7) Quickspecs

Table of Contents

Advertisement

QuickSpecs

Technical Specifications

System Unit
Dimensions (H x W x D)
(with bezel)
Weight
(approximate)
Power Specifications
System Inlet
Temperature
Relative Humidity
(non-condensing)
Altitude
DA - 13711 North America — Version 16 — September 24, 2012
HP ProLiant BL490c Generation 7 (G7) Server Blade
7.154 x 2.19 x 20.058 in (18.17 x 5.56 x 50.95 cm)
Maximum
(all hard drives and
processors installed)
Minimum
(one hard drive and
processor installed)
For power specifications including Input Requirements, BTU Rating, and Power
Supply Output, please see the HP BladeSystem c-Class Enclosures QuickSpecs
located at URL:
HP BladeSystem c3000 Enclosure QuickSpecs:
http://h18000.www1.hp.com/products/quickspecs/12790_na/
12790_na.html
HP BladeSystem c7000 Enclosure QuickSpecs:
http://h18000.www1.hp.com/products/quickspecs/12810_na/
12810_na.html
To review typical system power ratings use the HP BladeSystem Power Sizer
which is available via the online tool located at URL:
http://www.hp.com/go/bladesystem/powercalculator
NOTE: For optimal cooling and system performance the BL490c G7 requires
the c7000 enclosure to be configured with 10 fans and the c3000 enclosure to
be configured with 6 fans.
Operating
Non-operating
Operating
Non-operating
Operating
14.20 lb (6.44 kg)
10.75 lb (4.87 kg)
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m (1.8°F
per every 1000 ft) above sea level to a maximum
of 3050 m (10,000 ft), no direct sustained
sunlight. Maximum rate of change is 10°C/hr
(18°F/hr). The upper limit may be limited by the
type and number of options installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
5 to 95% relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, non-
condensing.
3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Page 34

Advertisement

Table of Contents
loading

Table of Contents