Error Messages - Avery Dennison ALS 341 User Manual

Fully automatic labeller
Table of Contents

Advertisement

Operators Manual
ALS 341

5.2 Error messages

For most of these errors, the labeller can not operate until the cause of the error is removed.
The labeller stops operating and a signal is supplied at the error output. You may restart the
labeller by pressing the ENTER key once you have cleared the error situation. The ready
output goes off.
Message
Description
F1
Loop will not be filled loop sensor not
activated
F2
Labeller doesn't detect the start of a
new label
F3
Indicates a problem with the rewind
function.
E_15
Short circuit or fault condition on of the
outputs of CN10.
If the problem reoccurs and in all other cases you need to call your Service Technician.
Release 4/04
How to solve
Normal if end of material else
pressure roller not closed
check function of loop sensor
clean mirror
readjust potentiometer of loop
sensor
unwind motor is not running
Normal message at
End of label material
More than 3 missing label on the
web
else check
pressure roller not closed
label web is not correctly
threaded through the label sensor
Label did not start from the
correct start position
while the label sticks to the
product, it pulls the backing
material may be because of
different dispense and product
speeds
Label length is shorter than label
pitch entered
Wrong adjustment of label sensor
CONT
Loop empty
drive motor is not running
End of material or label web broken
Check if rewind motor is running at all
Check the connections on the
outputs. Call the function O_CH to
get more information.
Page 28
Messages and Troubleshooting

Advertisement

Table of Contents
loading

Table of Contents