Operators Manual
ALS 341
2. Short form instruction
This chapter contains a short instruction to handle the machine.
CAUTION! - The machine is connected to mains. Only authorised personnel
may open the cover. Operation without this cover is not allowed.
Note: This manual applies to ALS341/441 machines equipped with software
version 4.3 or higher.
2.1 Operator panel
During normal operation the keys on the panel has the following functions:
Figure 1 Operating panel
Feed:
Dispense one label. Used to position the labels correct, after threading new
material or fixing an error situation.
Speed:
Setting the dispensing speed faster (up) or slower (down). The display shows
S250, which means a dispense speed of 25.0 m/min. With the both keys a value
from 2m/min up to 55m/min can be set.
Position:
Adjust the position of the label onto the product. The display message 0500
means that the dispensing will be started 50.0 mm after triggering the product
sensor by the product. Pressing the key
Release 4/04
decrease the shown value. The label
Page 9
Short form instruction