Stepper Motor Control - Avery Dennison ALS 341 User Manual

Fully automatic labeller
Table of Contents

Advertisement

Operators Manual
ALS 341

6.3 Stepper motor control

Voltage fault
Ready Emitter
Figure 14 Stepper motor control
Jumper for current level setting normally set towards the centre of the board for 5.6 A.
To reduce heat, the current for the loop motor could be set to 4A for small labels and low
production rate.
The jumper for the stepper resolution is open.
For connection with an old 6 pole cable, plug in the connector that the ready output is not used.
WARNING! - The electronic is driven by high voltage.
Don't touch the board if the machine is switched on.
The operation of the board is only allowed with connected motor.
Don't handle any connector or jumper during operation.
It is strictly prohibited to do any modification or repair onto the board.
Especially the fuse should not replaced and the pot should not be
disadjusted.
Release 4/04
Jumper for current selection
LED
Ready
+ Direction
- Direction
Jumper for current setting
+ Clock
- Clock
+ Boost
- Boost
Page 33
Jumper for resolution
5,6A
200 Schr
4A
Electrical connections
110VAC
110VAC
Phase1
Phase1
Phase2
Phase2

Advertisement

Table of Contents
loading

Table of Contents