ALS 341

6.4 CPU - board

The LED's of CPU-board indicated the following functions:
D1
error output active (only valid if a minimum load of 10kΩ on all outputs of CN10)
D2
24 V in order
D3
12V in order
D4
5V in order
Figure 15 Layout CPU board
Plug connector (in- and output ports)
CN 1
CN 5
CN 6
CN 10
CN 14, 15, 22:
CN 19 or 21:
a label sensor. If standard label sensor is in use, jumper J3 must be fitted,
in order to have 12 V supply voltage available. Other label sensor must be
connected to CN 21 and J3 taken off, to ensure 24 V supply voltage.
Release 4/04
24 V supply voltage
Opto coupler inputs
Opto coupler outputs
PNP output driver
Opto coupler sensor inputs
Label sensor alternatively you may use one of the 2 plugs for connecting