Trane Tracer AH540 Setup And Operation page 91

Air-handler controller
Hide thumbs Also See for Tracer AH540:
Table of Contents

Advertisement

Table 53. Timer configuration
Parameter
Power-up control wait
Maintenance required time setpoint
(based on fan run hours)
Occupancy bypass timer
Space temperature control
Occupancy bypass timer
Discharge air control
2
Maximum heat delay
1 The occupied bypass time is used for timed override applications when a building automation system is not present or when the
building automation system does not send the occupied (override) request. The timed override timer is maintained in the unit
controller. When the timed override is applicable, the controller reports Occupied Bypass as its effective occupancy mode.
2 Amount of time a variable-air-volume unit will delay electric heat operation on a transition from occupied to daytime warm-up
operation.
Table 54. Diagnostic alarm level configuration
Parameter
1
Diagnostic alarm level
2
Diagnostic language
1 Duct Static Pressure Failure, Duct Static Pressure High Limit, Space Temperature Failure, Discharge Air Temperature Failure, Unit
Shutdown, Low Temperature Detect, and Low Supply Fan Air Flow diagnostics can be configured as a group to be either service
required or critical alarm diagnostics; the diagnostics cannot be individually configured.
2 Alarm message text that will be communicated to the building automation system.
Table 55. Analog electric heat sequencer control configuration
1
Range
Parameter
Stage 1 On
0 to 10 V
Stage 1 Off
0 to 10 V
Stage 2 On
0 to 10 V
Stage 2 Off
0 to 10 V
Stage 3 On
0 to 10 V
Stage 3 Off
0 to 10 V
Stage 4 On
0 to 10 V
Stage 4 Off
0 to 10 V
Stage 5 On
0 to 10 V
Stage 5 Off
0 to 10 V
Stage 6 On
0 to 10 V
Stage 6 Off
0 to 10 V
1 These set-up parameters are required for Tracer AH540/541 to properly stage electric heat when a step controller is connected
to analog output AO3. The controller assumes each stage On and Off voltage threshold matches the step controller setup.
CNT-SVX05B-EN
1
0 to 240 minutes (1-minute resolution)
1
• Service required
• Critical alarm
• English
• Spanish
• French
Default
value
1 stage
4.2 V
0 V
5.2 V
3.6 V
6.3 V
4.7 V
7.4 V
5.7 V
8.4 V
6.8 V
10.0 V
7.8 V
Valid range
0 to 1000 seconds
0 to 10,000 hours
0 to 100% (1-minute resolution)
0 to 60 seconds
Valid range
Default value
2 stage
3 stage
10.0
6.6
5.6
0.0
0.0
0.0
10.0
10.0
7.4
10.0
5.4
4.7
10.0
10.0
10.0
10.0
10.0
6.4
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
Configuration
Default value
300 seconds
600 hours
120 minutes
50%
240 seconds (4 minutes)
Default value
Service required
English
4 stage
5 stage
4.9
4.5
0.0
0.0
6.4
5.7
4.2
3.8
7.8
7.0
5.6
5.1
10.0
8.2
7.1
6.3
10.0
10.0
10.0
7.5
10.0
10.0
10.0
10.0
6 stage
4.2
0.0
5.2
3.6
6.3
4.7
7.4
5.7
8.4
6.8
10.0
7.8
81