6. LOCAL DIAGNOSTICS TEST

Before testing, remove the plastic cover and then open the
battery cover (see Fig. 3).
A. Press the self-test button once and release it; the
following procedure should occur in turn:
The red LED will switch ON and then OFF, the green
LED will switch ON and then OFF, the strobe light will
switch ON and then OFF and the piezo siren will sound
to indicate that the siren is now fully operational.
B. After 2 seconds the LED blinks 3 times.
The following table indicates received signal strength
indication.
26
LED response
Green LED blinks
Orange LED blinks
Red LED blinks
No blinks
IMPORTANT! Reliable reception must be assured.
Therefore, "poor" signal strength is not acceptable. If you
receive a "poor" signal from the device, re-locate it and re-
test until a "good" or "strong" signal strength is received.
Note: For detailed Diagnostics Test instructions refer to
PowerMax10-G2 Installer Guide.
Reception
Strong
Good
Poor
No communication