Enrollment; Modify Device Settings; Local Diagnostics Test; Miscellaneous Comments - Visonic Fully supervised wireless accessories Accessories Manual

Fully supervised wireless accessories for powermax systems
Table of Contents

Advertisement

MOUNT THE MAGNET NEAR ITS
LOCATION MARK WITH 2 SCREWS
Figure 3b. Mounting

4. ENROLLMENT

Refer to the PowerMax10-G2 Installer Guide for the device enrollment procedure.

5. MODIFY DEVICE SETTINGS

This section describes how to configure the parameters of contact sensors from the PowerMax10-G2 control panel.
To Modify the Contact Sensor Settings
Refer to the PowerMax10-G2 Installer Guide and perform the procedure for Adding A Wireless Device (section 4.4.2), or,
Modifying a Device (section 4.4.5). Then continue below to modify the device settings.
1.
When the PowerMax10-G2 display reads [ DEV SETTINGS ], press
The PowerMax10-G2 display will read [Alarm LED].
2.
Press the
I
OK
The PowerMax10-G2 display will read [LED ON
3.
Press the
for example, "LED OFF".
4.
Press
to confirm the selection.
I
OK
The PowerMax10-G2 display will revert to [Alarm LED].
When exiting "
ZONES / DEVICES
number of devices that need to be updated, as follows: DEV UPDATING NNN.
For detailed instructions on ADDING DEVICES, DELETING DEVICES and
MODIFYING DEVICES see the PowerMax10-G2 Installer Guide.

6. LOCAL DIAGNOSTICS TEST

Before testing, separate the base from the cover (see Fig.
3a).
A. Press the tamper switch once and release it.
B. Put back the cover to return the tamper switch to its
normal (undisturbed) position, and then secure the front
cover to the base with the case closure screw.
C. Momentarily open the door or window and verify the red
LED blinks, indicating detection.
D. After 2 seconds the LED blinks 3 times.
The following table indicates received signal strength
indication.
LED response
Green LED blinks
Orange LED blinks
Red LED blinks
No blinks
D-302758
FIXED FRAME
MOVING PART
5
button.
or
button to select between "LED ON" and "LED OFF",
" menu the PowerMax10-G2 system displays the
Reception
Strong
Good
Poor
No communication
.
I
OK
].
IMPORTANT! Reliable reception must be assured.
Therefore, "poor" signal strength is not acceptable. If you
receive a "poor" signal from the device, re-locate it and re-
test until a "good" or "strong" signal strength is received.
Note: For detailed Diagnostics Test instructions refer to
PowerMax10-G2 Installer Guide.

7. MISCELLANEOUS COMMENTS

Visonic Ltd. wireless systems are very reliable and are
tested to high standards. However, due to low transmitting
power and limited range (required by FCC and other
regulatory authorities), there are some limitations to be
considered:
A. Receivers may be blocked by radio signals occurring on
or near their operating frequencies, regardless of the
digital code used.
B. A receiver responds only to one transmitted signal at a
time.
MC-302 PG2
I
OK
Alarm LED
I
OK
LED ON
or
LED OFF
I
OK
LED OFF
Alarm LED
17