Traffic Measurement and Reporting

TM Output Statistics

TM Output Statistics
The TM information collected is sent from the report buffer each hour. It is compiled into the output
format, then output to specified output port, and the SD/SM card if installed. Reports are sent to the
I/O or LAN port and the SD/SM card at the same time. Naming rules of output files are the same as
CIX/CTX event trace files:
MMDDHHNN.trf
MM: Month (Japanese style, 01-12)
DD: Day (01-31)
HH: Hour (01-23)
NN: Sequence Number*
*Sequence Number indicates the file number created in same hour.
For example: 10211600.trf is the file containing traffic information from 16:00 p.m. to 17:00 p.m.
on October 21.
Once the report output is completed, the statistics in the report buffer is cleared. However, if it isn't
completed for some reason, that buffer isn't cleared.
System administrator can request to re-output statistics report with a programming command that
includes the start and end times.
Statistics under measurement at the time a report is requested cannot be outputted. The report is only
available after the end time. For example; the traffic measurement data for 10 to 11 is not available
until after 11.
TM data is recorded each hour. A Traffic Report is requested using eManager to enter the
programming parameters to specify the report Start date and time, and the end date and time. The
traffic report is output to file named traffic.trf on the SD/SM card. If a traffic.trf file already exists
on the card the new file will over-write it.
Note The Traffic Measurement is system based. The measurement cannot be set to report per
tenant.

Capacities

The system provides up to three time zones. Each time zone must be a minimum of one hour to a
maximum of 24 hours. Overlapping of time zones is not allowed. A time zone across two days is
not allowed.
The system supports up to 64 OLGs and 64 ILGs for measurement.
The system supports up to 130 DID numbers for measurement (per 1 system).
When measuring under the following conditions, CIX can accumulate the statistics for 1 week in
the buffer.
Programming about this feature is not changed.
CIX time setting is not changed.
Switching to summer / normal time is not occured.
CIX is not restarted.
CIX is not turned off.