eMonitor/Alarm Notification
Strata CIX Network eMonitor
1. Select a Telephone System from the CIX equipment list displayed on the screen. If the desired
equipment name is not found, type in a name in the CIX Name field and click Add.
Note
2. Fill in the rest of the fields based on the descriptions shown in
3. Click Test Connection to make sure the connection is active.
Table 5
Equipment Setup Screen Fields
F
IELD
CIX Name
eMonitor Mode
CIX IP Address
CIX Community Name
Confirm CIX Community
Name
Test Connection Status
5-10
To delete an CIX name, highlight it on the list and click Delete.
D
ESCRIPTION
Name designating the equipment. For example: CIX670. This name appears in each
alarm and in the email notification of the alarms.
Possible values: alphanumeric characters
Note The System ID is programmed in the CIX database Alarm Control setup (Prog.
919), it is not entered from the eMonitor Profiles setup. The System Name is
entered in the eMonitor Profiles setup. The System ID and System Name do not
need to be the same.
Provides information on connections.
Command monitor is for equipment that resides in a Local Area Network (LAN)
environment with the IP address accessible to the eMonitor server. It provides the
following information on the equipment:
listen trap, collects extended alarm, clears CIX alarm buffer, test connection, setup alarm
notification, alarm viewer and system detail page.
Monitor Only is for equipment that resides behind a firewall or Network Address
Translator (NAT) in which the IP address is not published or accessible by the eMonitor
server. It provides the following information: Listen Trap, Alarm viewer. In Monitor Only
mode, the system can only listen but can not send commands.
If you select Monitor only mode, the following fields are grayed out:
Community Name, Confirm Community Name, Test Connection. The following is not
displayed: System Label, Test Connection Status.
Possible values: command monitor, monitor only
Default: Command monitor mode
Enter the IP Address of the CIX system. For example: 192.168.254.253.
Format: xxx.xxx.xxx.xxx
Enter the CIX Community password.
Possible values: Alpha characters
Default:
Re-enter the CIX Community password.
Results from performing Test Connection using the CIX IP Address and CIX Community
Name. This Test Connection is similar to a "ping" test except it also checks the
community name. If the connection failed, you would see a pop-up box and it would tell
you why the connection could not be made.
Note Test Connection will not function if the eMonitor server is behind a NAT router.
communityName
Strata CTX Application Implementation Vol 3
Table 5
below.
10/07