Note
Static electricity can damage
electronic circuitry. Before
removing the enclosure,
discharge any accumulated
static electricity from your
body by touching a grounded
metal object.
Figure 11
Pan-head screws locations
AXB-F117 Stealth 1 Camera Controller
Setting Internal Jumpers to AXlink or RS-232 Communication
Mode
Jumpers E5 through E7, located on the circuit card inside the AXB-F117, set the
communication mode to AXlink (factory default) or RS-232. You need a Phillips-
head screwdriver to open the unit and non-conducting pliers to set the jumpers.
1.
Discharge the static electricity from your body.
2.
Unplug all connectors from the rear panel of the AXB-F117.
3.
Remove the four pan-head screws from the left and right side of the AXB-F117
unit as shown in Figure 11.
4.
Carefully pull the back panel away from the main unit far enough to lay the
back panel down on a flat surface, and locate the E5, E6, and E7
communication mode jumpers (Figure 12).
Pan-head screws (two
screws on each side)