Installation
RS-232/RS-422/RS-485 connections
FIG. 4 shows the RS-232/RS-422/RS-485 DB-9 (male) connector pinouts. The table below lists the
connector pins, signal types, and signal functions.
Pin 1
FIG. 4 RS-232/422/485 DB-9 (male) connector pinouts
DB-9 Pinouts
Pin
Signal
1
RX-
2
RXD
3
TXD
4
TX+
5
GND
6
RX+
7
RTS
8
CTS
9
TX-
Using the AXlink connector for data and power
Connect the 4-pin AXlink connector to an external AXlink device, as shown in FIG. 5.
PWR+
AXP/TX
AXM/RX
GND-
AXlink/PWR connector
FIG. 5 AXlink/PWR data and power wiring diagram
Using the AXlink connector for data with a separate 12 VDC power supply
Connect the 4-pin AXlink connector to an external AXlink device; connect the 2-pin PWR
connector to the separate 12 VDC power supply as shown in FIG. 6. Make sure to connect only the
PWR+
AXP/TX
AXM/RX
GND-
FIG. 6 AXlink/PWR and optional 12 VDC power supply wiring diagram
6
Pin 9
Wiring and Baud Configurations
Function
RS-232
Receive data
Receive data
Transmit data
Transmit data
Signal ground
Receive data
Request to send
Clear to send
Transmit data
The X's show where to terminate the wires on the DB-9 connector.
PWR+
GND-
PWR+
AXP
AXM
GND-
3
Axcent
RS-422
RS-485
X
X (strap to pin 9)
X
X
X
X (strap to pin 6)
X
X
X
X (strap to pin 4)
X
X
X
X (strap to pin 1)
PWR+
AXP
External AXlink device
AXM
GND-
Local 12 VDC power supply
for ext. AXlink device
External AXlink device
3
Axcent
and Axcent
3
Pro Integrated Axcess Controllers
Need help?
Do you have a question about the AXCENT3 AND AXCENT3 PRO INTEGRATED AXCESS SYSTEM and is the answer not in the manual?