Figure 8
RS-232 DIP switch (S1)
settings
Note
After setting the AXlink device
number, remove and
reconnect the AXlink
connector on the AXB-F117
to store the new number into
memory.
Figure 9
AXlink Device DIP switch
(S2) example
Figure 10
Device DIP switch (S2)
positions and values
8
Pre-Installation Settings
RS-232 DIP switch (S1) settings
Position
1
Function
Stop Bits
Data Bits
Off
2 bits
On
1 bit

Setting the AXlink Device DIP switch (S2)

The 8-position Device DIP switch (S2), shown in Figure 9, sets the AXlink device
number. The device number must match the number assigned in the AXCESS
software program. The AXlink device number range is 1-255, and is sent according
to the Device DIP switch positions and their values (Figure 10). The Device DIP
switch example shown in Figure 9 is set to 90 (2 + 8 + 16 + 64 = 90), which is the
factory default setting.
S2
1 2 3 4 5 6 7 8
ON
DEVICE
Device DIP switch (S2) settings
Position
1
2
Value
1
2
2
3
4
Parity
Off
Off
Off
7 bits
Unused
On
On
Off
8 bits
Unused
Off
On
Unused
On
On
Unused
Off
Off
Unused
On
Off
Even
Off
On
Odd
On
On
None
3
4
5
6
4
8
16
32
5
6
7
Baud Rate
Off
Off
Off
300
Off
On
Off
600
Off
Off
On
1,200
Off
On
On
2,400
On
Off
Off
4,800
On
On
Off
9,600
On
Off
On
19,200
On
On
On
38,400
7
8
64
128
AXB-F117 Stealth 1 Camera Controller
8
Off
Off
Off
Off
On
On
On
On