Port Configuration - Allied Telesis AT-4016TR Operation Manual

Ethernet switch with atm access
Hide thumbs Also See for AT-4016TR:
Table of Contents

Advertisement

Port Configuration
Received BPDUs will be submitted for transmission. They will also be
processed as required by the STP algorithm.
indicates a port that is NOT PARTICIPATING in frame relay. Nor
Disabled
is it participating in the operation of the STP algorithm and protocol.
Received frames are discarded. Submitted frames are not forwarded for
transmission.
Disabled is left when the port is enabled by management action and the
blocking state is entered.
Polarity. The
Polarity
pair polarity: either
Normal
indicates correct polarity.
Normal
indicates incorrect polarity — software has detected that
Reversed
your wiring has been installed with reversed polarity. It has also
subsequently corrected it. Operator intervention is not required.
To change port information, enter a port number from the Port Status menu.
The Port Configuration Menu appears. In this case, port #16 was selected.
The system and port name appear at the top of the screen. Below that is the
port's status and configuration. And, below that, you see three menu options.
The following configuration options are available:
Enable/Disable. Selecting
transmit or receive data. Selecting
preventing port traffic.
column shows the state of each UTP port's receive
or
.
Reversed
changes the port's state to allow it to
Enable
turns the port logically off, thus
Disable
AT-S7/AT-S9 Operations Manual