General System Configuration - Allied Telesis AT-4016TR Operation Manual

Ethernet switch with atm access
Hide thumbs Also See for AT-4016TR:
Table of Contents

Advertisement

TFTP

General System Configuration

78
When you use TFTP, the file name for the switch must be the same as the
downloaded password. For example, if you had changed the default download
password to ALLIED, and the configuration file on your PC was
NEWCONF, your TFTP command line might look like the following:
TFTP PUT NEWCONF 135.24.35.122 ALLIED ASCII
Description
Terminal Baud Rate:
Allowable configuration data:
Default Value:
Terminal Parity:
Allowable configuration data:
Default Value:
Terminal Type:
Allowable configuration data:
Default Value:
Terminal Character Echo:
Allowable configuration data:
Default Value:
Terminal Cursor Home Position
Control Character Sequence:
Allowable configuration data:
Default Value:
FIELD IDENTIFIER and VALUEs
BAUD = 19200
AUTO, 192000, 9600, 4800, 2400, 1200, 600, 300,
150, 75
AUTO
PARITY = NONE
NONE, ODD, EVEN, MARK, SPACE
NONE
TERM TYPE = VT100
DUMB, VT100, USER
DUMB
CHAR ECHO = ECHO
ECHO, NO_ECHO
ECHO
HOME CURSOR =
"XXXXXXXXXXXXXXXXXXXX"
A maximum of twenty (20) ASCII characters
NULL