Page 2
Copyright ”1999 Allied Telesyn International, Corp. 960 Stewart Drive Suite B, Sunnyvale CA 94086, USA All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International, Corp. Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners.
Electrical Safety and Installation Requirements For AT-FS724I STANDARDS: This product meets the following standards U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Page 4
Electrical Safety and Installation Requirements For AT-FS724I STANDARDER: Dette produkt tilfredsstiller de følgende standarder. Radiofrekvens forstyrrelsesemission EN55022 Klasse A ADVARSEL: I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse. Bliver det tilfældet, påkræves brugeren muligvis at tage tilstrækkelige foranstaltninger. Immunitet EN50082-1 Elektrisk sikkerhed...
Page 5
AT-FS716, AT-FS716E, and AT-FS724I Switches Installation Guide SIKKERHETSNORMER: Dette produktet tilfredsstiller følgende sikkerhetsnormer. RFI stråling EN55022 Klasse A ADVARSEL: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler. Immunitet...
Electrical Safety and Installation Requirements For AT-FS716 and AT-FS716E Electrical Safety and Installation Requirements For AT-FS716 and AT-FS716E STANDARDS: This product meets the following standards. U.S. Federal Communications Commission DECLARATION OF CONFORMITY Manufacture Name: Allied Telesyn International Manufacture Address: 950 Kifer Road...
Page 7
AT-FS716, AT-FS716E, and AT-FS724I Switches Installation Guide NORMEN: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen. Hochfrequenzstörung EN55022 Klasse B Störsicherheit EN50082-1 Elektrische Sicherheit TUV-EN60950, UL1950, CSA 950 STANDARDER: Dette produkt tilfredsstiller de følgende standarder. Radiofrekvens forstyrrelsesemission EN55022 Klasse B...
Page 8
Electrical Safety and Installation Requirements For AT-FS716 and AT-FS716E PADRÕES: Este produto atende aos seguintes padrões. Emissão de interferência de radiofrequência EN55022 Classe B Imunidade EN50082-1 Segurança Eléctrica TUV-EN60950, UL1950, CSA 950 ESTÁNDARES: Este producto cumple con los siguientes estándares.
AT-FS716, AT-FS716E, and AT-FS724I Switches Installation Guide Safety Information (All Products) SAFETY ELECTRICAL NOTICES WARNING: ELECTRIC SHOCK HAZARD To prevent ELECTRIC shock , do not remove cover. No user-serviceable parts inside. This unit contains HAZARDOUS VOLTAGES and should only be opened by a trained and qualified technician.
Page 10
Safety Information (All Products) NETZKABEL Das Netzkabel sollte eine maximale Länge von 4,5 Metern, einen Nennwert von mindestens 6 A und 250 V haben, aus HAR-Material hergestellt und mit einer gepreßten, IEC 320 entsprechenden, Anschlußverbindung an einem Ende, und am anderen Ende mit einem im Land des Endverbrauchers geprüften Stecker ausgestattet sein.
Page 11
AT-FS716, AT-FS716E, and AT-FS724I Switches Installation Guide VEILIGHEID WAARSCHUWINGEN MET BETREKKING TOT ELEKTRICITEIT WAARSCHUWING: GEVAAR VOOR ELEKTRISCHE SCHOKKEN Verwijder het deksel niet, teneinde ELEKTRISCHE schokken te voorkomen. Binnenin bevinden zich geen onderdelen die door de gebruiker onderhouden kunnen worden. Dit toestel staat onder GEVAARLIJKE SPANNING en mag alleen worden geopend door een daartoe opgeleide en bevoegde technicus.
Page 12
Safety Information (All Products) ÉQUIPEMENT DE CLASSE 1 ÉLECTRIQUE CE MATÉRIEL DOIT ÊTRE MIS A LA TERRE. La prise de courant doit être branchée dans une prise femelle correctement mise à la terre car des tensions dangereuses risqueraient d’atteindre les pièces métalliques accessibles à l’utilisateur. INFORMATION SUR LE CORDON ÉLECTRIQUE Utiliser un cordon secteur de 4.5 mètres de long maximum, calibré...
Page 13
AT-FS716, AT-FS716E, and AT-FS724I Switches Installation Guide NORME DI SICUREZZA AVVERTENZE ELETTRICHE ATTENZIONE: PERICOLO DI SCOSSE ELETTRICHE Per evitare SCOSSE ELETTRICHE non asportare il coperchio. Le componenti interne non sono riparabili dall’utente. Questa unità ha TENSIONI PERICOLOSE e va aperta solamente da un tecnico specializzato e qualificato.
Page 14
Safety Information (All Products) ELEKTRISK—TYPE 1- KLASSE UTSTYR DETTE UTSTYRET MÅ JORDES. Strømkontakten må være tilkoplet en korrekt jordet kontakt. En kontakt som ikke er korrekt jordet kan føre til farlig spenninger i lett t ilgjengelige metalldeler. ELEKTRISK—MEDDELELSE OM LEDNINGER Bruk en strømledning av maksimalt 4.5 m.
Page 15
AT-FS716, AT-FS716E, and AT-FS724I Switches Installation Guide SEGURIDAD AVISOS ELECTRICOS ADVERTENCIA: PELIGRO DE ELECTROCHOQUE Para evitar un ELECTROCHOQUE, no quite la tapa. No hay ningún componente en el interior al cual puede prestar servicio el usuario. Esta unidad contiene VOLTAJES PELIGROSOS y sólo deberá...
Page 16
Safety Information (All Products) ELEKTRISKT —ANMÄRKNING BETRÄFFANDE KABELN Använd en kabel med maximum längd 4,5 meter och minimum 6 amp nominal, 250V, av HAR kabelfabrikat med ett specialutformat IEC 320-kontaktdon i ena änden och i den andra en plugg som godkänts i landet där produkten används. VARNING: Luftventilerna får ej blockeras och måste ha fri tillgång till omgivande rumsluft för avsvalning.
Table of Contents Electrical Safety and Installation Requirements For AT-FS724I ........iii Electrical Safety and Installation Requirements For AT-FS716 and AT-FS716E ....vi Safety Information (All Products) ..................ix Chapter 1 Product Description ......................1 Overview ..........................1 Common Major Features .......................2 Physical Description........................3 Front Panel LEDs......................3...
Page 18
100Base-TX Connector Pinouts ..................20 Straight-through Cable ....................20 Crossover Cable......................20 Appendix B Technical Support Fax Order ..................... 21 Incident Summary........................ 21 Appendix C AT-FS716, AT-FS716E, and AT-FS724I Switches Installation Feedback ....... 23 Appendix D Where To Find Us ....................... 25 xviii...
Chapter 1 Product Description Overview This chapter describes the features of the following unmanaged Fast Ethernet switches: ‰ AT-FS716 ‰ AT-FS716E ‰ AT-FS724I Each switch model is described in Table 1. Table 1 Switch Models and Port Description Model Description...
Fast Ethernet products, providing simple, cost-effective solutions for switching between 10 and 100 Mbps. Easy to install, simply connect your 10Base-T or 100Base-TX station ports, and plug in the power. Figures 1 show the front panel of the AT-FS716 switch. The AT-FS716E and AT-FS724I front panels are similar.
AT-FS716, AT-FS716E, and AT-FS724I Switches Installation Guide Figure 1 AT-FS716 Front Panel Physical Description The physical description for the switches includes: ‰ Media-Dependent Interface (MDI)/ MDI-X push button setting, Port 16 or Port 24 ‰ LEDs ‰ Power supply Front Panel LEDs Figure 2 shows the layout of the front panel LEDs;...
Product Description Table 2 LED Status LEDs Color Description Off means there is no power to the switch. POWER Green On means there is power to the switch. On indicates a valid physical link on the port. LINK/ACTIVITY Green Blinking indicates data is being transmitted. Off means no link.
AT-FS716, AT-FS716E, and AT-FS724I Switches Installation Guide Power Supply The AT-FS716 and AT-FS724I use a universal internal switching power supply with 100 to 120 VAC, or 200 to 240 VAC, 50/60 Hz input rating. Allied Telesyn ships power cords with the units to the U.S., Continental Europe, and the U.K.
Verifying Package Contents Make sure that the package includes the following items: ‰ One AT-FS716, AT-FS716E, or AT-FS724I switch ‰ One AC power cord (AT-FS716 or AT-FS724I) or power adapter (AT-FS716E) ‰ Two rackmounting brackets with screws (AT-FS716 or AT-FS724I only) ‰...
2. Place the switch on a flat, level surface where power is easily accessible. 3. Connect power: — For AT-FS716 and AT-FS724I, attach one end of the power cord to the back of the switch and the other end to the power source.
AT-FS716, AT-FS716E, and AT-724I Switches Installation Guide Rackmount Installation Rackmount installation applies to the AT-FS716 and AT-FS724 only. You will need a Phillips screwdriver for this installation. Caution Do not use power tools to perform this installation. If previously attached, remove the rubber feet and all cables and power cord from the switch.
Cat 5, UTP wiring Figure 3 AT-FS716 Connected to End Stations Cascade Configuration Cascading means that two switches can be connected together using any of the switch ports provided you maintain the same medium type.
AT-FS716, AT-FS716E, and AT-724I Switches Installation Guide Port 16 MDI 100 Mbps Figure 4 Cascading Switches /LQNî$FWLYLW\ý 3. Check the front panels to make sure that the green lights. Uplink Configuration For 100 Mbps connection to the backbone, use Port 16/24 with the switch set for 0',ñýDQGý...
Chapter 3 Troubleshooting This chapter describes the procedures to test and troubleshoot the switches. Connectivity Testing In the following procedure, you will test each port for a valid connection and to confirm the correct operation of the network. Start with Ports 1 and 2. Connect these two ports of a single switch to two nodes or workstations and turn on the switch power.
Troubleshooting Problem Solving Is the unit receiving power? Check the Power LED on the front of the switch. This green LED should be lit. Note The switch performs a self-diagnostic test upon power on, and takes about 20 seconds to complete. If the Power LED is not on, check both ends of the power cord or adapter.
Page 33
AT-FS716, AT-FS716E, and AT-FS724I Switches Installation Guide 3. Problem 3: Port 16/24 does not work. ‰ Solution 3: — Make sure you have the correct MDI/MDI-X push button setting for Port 16/24. Use MDI for uplink, MDI-X for a PC.
Up to 3,048 m (10,000 ft) Standards CE Compliant Functional: IEEE 802.3 10Base-T Ethernet IEEE 802.3u, 100Base-TX Fast Ethernet EMI/RFI: AT-FS716 and AT-FS716E: Meets FCC Class B, VCCI Class B, CISPR Class B AT-FS724: Meets FCC Class A, VCCI CLass A, CISPR Class A...
100 m (328 ft) is the maximum distance between switch and network node connections. Electrical Specifications AT-FS716 or AT-FS724I Internal Power: Internal universal power supply with 100 to 240 VAC, 50/60 Hz, 0.3 A input. AT-FS716E External Power: External power adaper provides 13-19 UDC, 800 mA maximum.
AT-FS716, AT-FS716E, and AT-FS724I Switches Installation Guide Network Specifications Table 4 provides an overview of IEEE 802.3 and 802.3u specifications for 10Base-T and 100Base-TX network configurations using shielded twisted-pair wiring. Table 4 IEEE 802.3 and 802.3u Network Specifications 10Base-T 100Base-TX...
Appendix B Technical Support Fax Order Name ___________________________________________________________________ Company ________________________________________________________________ Address _________________________________________________________________ City ________________________ State/Province ________________________________ Zip/Postal Code ___________________ Country _________________________________ Phone _______________________________Fax _________________________________ Incident Summary Model number of Allied Telesyn product I am using ______________________________ Network software products I am using _________________________________________ BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Brief summary of problem __________________________________________________ BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB...
Appendix C AT-FS716, AT-FS716E, and AT-FS724I Switches Installation Feedback Please tell us what additional information you would like to see discussed in the guide. If there are topics you would like information on that were not covered in the guide, please photocopy this page, answer the questions and fax or mail this form back to Allied Telesyn International Corp.
Appendix D Where To Find Us For Technical Support or Service Location Phone Americas 1 (800) 428-4835 1 (918) 628-3222 United States, Canada, Mexico, Central America, South America Asia (+65) 3815-613 (+65) 3833-830 Singapore, Taiwan, Thailand, Malaysia, Indonesia, Korea, Philippines, China, India Australia (+61) 2-943-5111 (+61) 2-9438-4966...