Installation instructions Gas hob KM 404 / KM 405 KM 406 KM 414 / KM 417 en - GB To avoid the risk of accidents or damage to the appliance, it is essential to read these instructions before it is installed and used for the first time.
Page 2
Per questo se si vuole usare l'apparecchio in un paese diverso rivolgersi al servizio di assistenza tecnica Miele del paese in cui si intende usarlo.
Page 3
Gas-heated appliances Safety precautions to take if you smell gas ß Turn off the gas emergency control valve immediately. This is usually located near the gas meter. ß Eliminate all sources of ignition in a safe manner. Do not smoke, light cigarette lighters or matches. ß...
Warning and Safety instructions An electric fryer must not be Safety distance above appliances installed next to a gas hob, as the gas flames could ignite the fat in the fryer. It is essential to maintain a distance of at least 288 mm between these two appliances.
Appliance dimensions KM 404 a Support bracket b Building in height plus 3 mm for fixing screw...
Page 9
Appliance dimensions KM 405 a Support bracket b Building in height plus 3 mm for fixing screw c Front d Building in height - Mains connection box e Gas connection...
Page 10
Appliance dimensions KM 406 a Support bracket b Building in height plus 3 mm for fixing screw...
Page 11
Appliance dimensions KM 414 a Support bracket b Building in height plus 3 mm for fixing screw...
Page 12
Appliance dimensions KM 417 a Support bracket b Building in height plus 3 mm for fixing screw c Front d Building in height - Mains connection box e Gas connection...
Worktop cut-out KM 404 / KM 405 / 406 Worktop cut-out KM 404 /405 /406 Depth Width Number (= Dim. B) in mm in mm appliances ± 1 mm ± 1 mm 1130 1418 1706 1994 Dimensions 7 mm and 11 mm are the space taken up by the frame of the appliance on the worktop.
Installation KM 404 / KM 405 / 406 Fitting the spacer bars and support brackets c Gap between spacer bar and a Support brackets worktop. b Spacer bars d Drilling for a granite worktop. Installation of several appliances ^ Fix the spacer bars b and the...
Installation KM 404 / KM 405 / 406 Fixing the spacer bars Granite worktops The spacer bar is only required when With granite worktops the spacer bars b must be positioned and secured with combined with another appliance. strong double-sided adhesive tape. In addition, coat the edges with silicone and fill in the gap c.
Installation KM 404 / KM 405 / 406 Fixing the support brackets Granite worktops On a granite worktop a hole must be drilled d at the position indicated to secure each support bracket. ^ Using a piece of strong, double-...
Worktop cut-out KM 414 / KM 417 Worktop cut-out KM 414 / 417 Depth in mm Width (= Dim. B) ± 1 mm in mm ± 1 mm 1 hob 552-560 Worktop cut-out KM 414 / 417 + 288 mm wide appliances Dimensions 7 mm and 11 mm are the Depth Width...
Installation KM 414 / KM 417 Fitting the spacer bars and support brackets KM 414 / KM 417 with 2 appliances 288 mm wide 2 7 6 1 1 2 8 4 3 1 2 8 8 1 3 3 KM 41 4 KM 41 7 5 6 3...
Installation KM 414 / KM 417 Fixing the spacer bars Granite worktops The spacer bar is only required when With granite worktops the spacer bars b must be positioned and secured with combined with a 288 mm wide combiset appliance. strong double-sided adhesive tape.
Installation KM 414 / KM 417 Fixing the support brackets Granite worktops On a granite worktop a hole must be drilled d at the position indicated to secure each support bracket. ^ Using a piece of strong, double- sided adhesive tape position the support brackets supplied a at the positions indicated flush with the top edge of the worktop and secure each...
General Important Under no circumstances should sealant find its way between the frame of the top part of the hob and the worktop. This could cause difficulties if the hob ever needs to be taken out for servicing, (possibly leading to damage to the frame and worktop).
Electrical connection Connection should be made via a All electrical work should be carried suitable isolator or a double pole fused out by a suitably qualified and spur connection unit which complies competent person, in strict with national and local safety accordance with current local and regulations and the on/off switch should national safety regulations (BS 7671...
Page 23
Electrical connection Important The electrical safety of this appliance can only be guaranteed when continuity is complete between it and an effective earthing system, which complies with current local and national safety regulations. It is most important that this basic safety requirement is present and regularly tested and where there is any doubt, the electrical wiring in the home should be tested by a...
Gas connection Connection Connection to the gas supply, or Conversion to another type of gas is conversion from one type of gas to described under the relevant Section. another should only be undertaken by an approved and registered gas The gas connection must be installed installer in strict accordance with so that connection can be made either local and national safety and...
Gas connection KM 404 / KM 405 / KM 406 Natural gas / liquid gas ^ An appropriate rigid connection and isolating valve must be installed for final connection. ^ The gas connection must be so sited that it is not adversely heated when the appliance is in operation.
Conversion to another type of gas KM 404 Jet table for U.K. and IE When converting to another type of gas, the main jets and the small jets Main of all burners must be changed. setting Ø Ø Natural gas...
Conversion to another type of gas Changing the jets Changing the small jets Disconnect the gas hob from the electricity supply by switching off at the socket and withdrawing the plug or by removing the mains fuse. Changing the main jets ^ Guide a screwdriver through the holes in the the lower casing of the hob and loosen the small jets f.
Conversion to another type of gas KM 405 Jet table for U.K. and IE When converting to another type of gas, the main jets and the small jets of all burners must be changed. Main setting Ø Ø Natural gas Nominal rating for all gas types with Normal burner 1.00...
Conversion to another type of gas Changing the jets Changing the small jets Disconnect the gas hob from the electricity supply by switching off at the socket and withdrawing the plug or by removing the mains fuse. Changing the main jets ^ Guide a screwdriver through the holes in the the lower casing of the hob and loosen the small jets f.
Conversion to another type of gas KM 406 Jet table For U.K. and IE When converting to another type of gas, the main jets and the small jets Main jet of all burners must be changed. Ø setting jet Ø Natural 1.85 0.88 / 0.40...
Conversion to another type of gas Changing the jets Disconnect the gas hob from the electricity supply by switching off at the socket and withdrawing the plug or by removing the mains fuse. ^ Pull the control knob for the gas burner upwards and off.
Page 32
Conversion to another type of gas Changing the main jet Changing the small jets ^ Use an SW 10 socket spanner to a Small jet with smaller jet diameter (e.g. for liquid gas: 0.20). loosen the main jet from its holder, by turning anti-clockwise.
Page 33
Conversion to another type of gas ^ Remove screw c from fitting b with Changing the jet for the inner burner an SW8 spanner and use an SW12 spanner to counterhold. ^ Then remove the screw fitting b from a with an SW12 spanner and use another SW12 spanner to counterhold.
Conversion to another type of gas ^ If this is not the case, loosen the Check the first intake of air securing screw, re-position the air sleeve and then tighten the securing screw. ^ Finally secure the jets against inadvertent loosening with sealing wax.
Conversion to another type of gas KM 414 Jet table for U.K. and IE When converting to another type of gas, the main jets and the small jets Main of all burners must be changed. setting Ø Ø Natural gas Nominal rating for all gas types with Normal burner 1.00...
Conversion to another type of gas Changing the jets Changing the small jet Disconnect the gas hob from the electricity supply by switching off at the socket and withdrawing the plug or by removing the mains fuse. Changing the main jet ^ Guide a screwdriver through the holes in the the lower casing of the hob and loosen the small jets f.
Conversion to another type of gas KM 417 Jet table for U.K. and IE When converting to another type of gas, the main jets and the small jets Main of all burners must be changed. setting Ø Ø Natural gas Nominal rating for all gas types with Normal burner 1.00...
Conversion to another type of gas Changing the jets Changing the small jets Disconnect the gas hob from the electricity supply by switching off at the socket and withdrawing the plug or by removing the mains fuse. Changing the main jets ^ Guide a screwdriver through the holes in the the lower casing of the hob and loosen the small jets f.