Fluke 2620A User Manual page 161

Hydra series ii data acquisition unit, hydra series ii data logger
Hide thumbs Also See for 2620A:
Table of Contents

Advertisement

Ohms Inputs
Range
Resolution
Slow
300
10 m
3 k
0.1
30 k
1
300 k
10
3 M
100
10 M
1 k
Range
90 Days, Slow
300
0.013% + 20 m
3 k
0.015% + 0.2
30 k
0.013% + 2
300 k
0.020% + 20
3 M
0.059% + 200
10 M
0.168% + 2 k
2-Wire Accuracy
Add 4.0 to accuracy specifications for channels 1 to 20, and add 20 m
Lead wire resistances are not included.
Input Protection
300V dc or ac rms on all ranges
Cross-Talk Rejection
Refer to Appendix D.
Typical Full
Scale Voltage
Fast
0.1
0.22 V
1
0.25V
10
0.29 V
100
0.68 V
1 k
2.25 V
10 k
2.72 V
4-Wire Accuracy ±(%± )
18°C to 28°C
1 Year, Slow
1 Year, Fast
0.014% + 20 m
0.014% + 0.2
0.016% + 0.2
0.016% + 2
0.014% + 2
0.014% + 20
0.021% + 20
0.021% + 200
0.063% + 200
0.063% + 2 k
0.169% + 2 k
0.709% + 20 k
Maximum
Maximum Open
Current
Through
Unknown
Circuit Voltage
1 mA
3.2V
110 A
1.5 V
13 A
1.5 V
3.2 . A
3.2 V
3.2 A
3.2 V
3.2 A
3.2 V
0°C to 60°C
1 Year, Slow
1 Year, Fast
0.031% + 20 m
0.031% + 0.2
0.039% + 0.2
0.039% + 2
0.039% + 2
0.039% + 20
0.050% + 20
0.050% + 200
0.231% + 200
0.231% + 2 k
0.573% + 2 k
0.923% + 20 k
for channel 0.
Appendices
A
Specifications
A-9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2625a