Installation With Other Equipment - Fujitsu TeamPoS 3600 Series Installation & Maintenance Manual

Table of Contents

Advertisement

PoS
Team
3600 Series
4.8

Installation with Other Equipment

In most cases, dedicated AC mains circuits are not required for the
terminal. In rare instances, other electrical equipment sharing power with the terminal may
cause adverse effects on the terminal. When this occurs, electrical isolation may be
required and is the responsibility of the customer or installing contractor.
Terminals at 100-240 volts
The table below details the power requirements for the
unit. Provide 100-240 volts AC, 50/60 Hz, single phase, with the following amperage
requirements:
Property
Grounding
Power system
Rated voltage and frequency
Rated current
Operational frequency limits
Earth leakage current
Power dissipation
Maximum HRC fuse rating for
external short-circuit protection
Main power cord:
Length
Diameter
Minimum bend radius
D900000338
Value or Description
The terminals are Class 1 equipment and must be supplied
via a socket outlet which has a protective ground contact
connected to the protective ground of the terminal.
The terminals are designed for use on a power system with
a grounded neutral, i.e., a TN or TT power system. The
terminals must not be directly connected to a power
system with impedance grounded neutral, i.e., an IT power
system.
100 - 240 volts, 50/60 Hz
6A max
47 – 63 Hz
< 1.0 mA
350 watts
10 A / 20 A
3.00 m (9.80 ft.)
8.0 mm (0.30 in.)
10.0 mm (0.40 in.)
Issue 3
Site Preparation
PoS
Team
PoS
Team
3600 Series
3600 Series
controller
4-7