Euphonix System 5 Installation Guide

FC631 Frame Controller

AES Sync In (3-pin Lemo Female): The DF64 Digital Frame clocks to the signal at this
port when the sync source is set to AES Sync. Connect this port to a digital sync reference.
AES Sync Out (3-pin Lemo Male): This signal is active regardless of the selected sync
source.
Word In (BNC): The DF64 clocks to the signal at this port when the sync source is set to
Word Clock. Connect this port to a digital sync reference.
Word Out (BNC): This signal is active regardless of selected sync source.
IEEE 1394 ports (2 ports, 6-pin IEEE 1394): High speed communication interface to the
PC254d Digital Pilot Computer. This interface carries real-time control and metering data
between the PC254d and the DF64. Connect either port to any of the IEEE 1394 ports on
the dedicated PC254d for this frame via provided IEEE-1394 (Firewire) cables.

MM641 MADI Interface Card

MADI In (4) and MADI Out (4) (8 BNC): Digital audio in and outs. See the MADI Hookup
diagrams beginning on page 26 for details on these connections.

SP661 Signal Processor

This card has no connections.

System 5 Console

The System 5 Console consists of several modular components: the CM401 and CM402
(console center section), the CM408 (contains eight physical faders and controls), the
CM403 (contains the joystick panner panel and film monitor panel), and the CM409HTP
Track Panner Module. Each component has the following connections:
Power Connectors (IEC): Accepts two standard IEC power cords (provided). Two autorang-
ing switching supplies accept voltages between 100–240 VAC, 50–60 Hz.
Power Status (DE-9): Offers two open-collector, optically-isolated power status feeds.
Pins 1/2 reference the primary power supply, and pins 3/4 the secondary. These outputs
are capable of switching a maximum of 20 mA at 24 VDC.
Network Port (RJ45): Connect to EuCon Network Hub via RJ45 through the console
ethernet harness (provided).
Expansion Port (DB-25): Active on the CM401 only. Connect talkback switches here.
35