Indoor residential gas fireplace
Hide thumbs Also See for H34DL:
Table of Contents

Advertisement

Installation & Maintenance Manual
DANGER
Read and understand this manual. Improper installation, adjustment, alteration,
service or maintenance can cause serious injury, property damage or even death.
For assistance or additional information consult a qualified installer, service
agency or the gas supplier.
Glass doors on gas fireplaces are extremely hot while the fireplace is on and
remain hot even after the fireplace has been turned off. Safety screens are
available and can reduce the risks of severe burns. Please keep children away
from the fireplace at all times.
XG0140
CAUTION
®
C
US
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
H34DL
HC34DL
H38DL
H42DL
Indoor
Residential
Gas Fireplace
WARNING
Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of
this or any other gas burning appliance. A fire or explosion my occur causing serious
injury, property damage or even death.
NOTICE
Installer: Leave this manual with the appliance. Do not remove.
Consumer: Retain this manual for maintenance and future reference. Do not Discard.
DANGER
Blank
IF YOU SMELL GAS
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not try to light any appliance.
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not touch any electrical switch; do not use any phone in your building.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Flammable materials
Explosion risk
Immediately call your gas supplier from a neighbor's phone. Follow the gas
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Blank
supplier's instructions.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Flammable materials
falling objects
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
If you cannot reach your gas supplier, call the fire department.
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Low temperature
Strong magnetic field
falling objects
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
(mobile home)
120611

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H34DL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Montigo H34DL

  • Page 1 Danger of harming radiation Environment your hands Gas bottles Watch for Electricity Danger for cutter Entrapment hazard Battery hazard Rotating parts falling objects XG0140 120611 Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248...
  • Page 2: Table Of Contents

    General ▪ ........11 Section 3-3-1: Venting Layout ▪ ..............29 Cleaning ▪ ....11 Top Vent, Wall mounted Graph, H34DL ▪ ......... 29 Hi-Lo Burner Adjustment ▪ ....11 Top Vent, Wall mounted Graph, H38DL ▪ ........... 29 Pilot Burner Adjustment ▪...
  • Page 3: Safety Alert Key

    INTRODUCTION Congratulations on your purchase of a Montigo Fireplace. With over 30 years of experience, Montigo is committed to providing you with a gas fireplace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest safety, reliability and engineering standards.
  • Page 4: Installation

    Montigo Power Vent. Lay out the Vent run; calculating the required elbows and „ straight runs of 4"/7" for H34DL or 5"/8" for H38DL & H42DL flex or rigid pipe. Layout Electrical Requirements Refer to Section 4: Wiring, for „...
  • Page 5: Section 1: Installation Overview And Product Dimensions

    Direct Vent installation. The fireplace dimensions are shown below: Top View Front View LH-Side View H34DL* H38DL* H42DL* Figure 1. Fireplace dimensions (Tolerance ± ⅛"). Page 5 XG0140 - 120611.1...
  • Page 6: Framing The Fireplace

    37 1/4 33 3/4 17 7/8 52 3/8 materials. H34DL* For Top Vent applications, the minimum clearance is 2" from the rear of 40 1/4 37 3/4 18 7/8 57 1/2 40 5/8 H38DL* the fireplace to a wall, or any combustible materials, and 17 1/2"...
  • Page 7: The Direct Vent System

    Section 3: Venting Section 3-1: CONVERTING TO REAR VENT Montigo supplies a variety of direct venting and termination options. The direct vent termination location MUST be selected such that NOTE: H42DLL* Propane models MUST be installed in a top vent it is the highest point in the venting assembly.
  • Page 8: Section 3-2: Installing A Roof Mounted Termination

    H-Series DL Indoor Gas Fireplace Installation Section 3-2: INSTALLING A ROOF MOUNTED DIRECT VENT PVTK1 MVTK-1 / PVTK-1 Termination Termination TERMINATION (MVTK-1SS / PVTK-1SS) 2’ min. This section applies to installations where the direct vent termination will be roof mounted. Support ring Section 3-2-1: VENTING LAYOUT...
  • Page 9: Standard Roof Vent (One Elbows No Offsets)

    H-Series DL Gas Fireplace Installation MVTK-1 / PVTK-1 PVTK1 Termination Termination MEXT/PEXT Sections Support plate 32’ max Support ring 18” Max. Figure 8c. Rear vent, Roof mounted venting (1 = 90° bend). Page 9 XG0140 - 120611.1...
  • Page 10: Section 3-3: Installing A Wall Mounted Termination

    H-Series DL Indoor Gas Fireplace Installation Section 3-3: INSTALLING A WALL MOUNTED DIRECT VENT 4). Installation of termination from inside structure TERMINATION A Termination with a MOSR Frame is installed from the inside of the This section applies to installations where the direct vent termi- structure.
  • Page 11: Section 3-3-1: Venting Layout

    All measurements for vertical or horizontal runs are measured „ please contact a local Montigo from center of the vent pipe. dealer for Power Venting options. Venting runs must fall within the limits set by the venting graphs, „...
  • Page 12: Top Vent, Wall Mounted Graph, H42Dl

    45” Flex Section If your installation does not fall 36 ” within the venting graph parameters, please contact a local Montigo Exterior dealer for Power Venting options. Wall Hearth Figure 13 H42DL* Top Vent Venting Graph for wall mounted terminations, Figure 14a.
  • Page 13: Rear Vent, Wall Mounted Graph, H34Dl

    WARNING: Horizontal Run (in.) An inspection of the explosion relief flappers and door Figure 15. H34DL* Rear Vent Venting Graph for wall mounted terminations, MUST be made prior to lighting the fireplace. Faulty seal See Figures 18a & 18b. on the door gasket and/or explosion ports will result in products of combustion leaking into the living space and may result in carbon monoxide poisoning.
  • Page 14: Rear Vent, Wall Mounted Graph, H42Dl

    31 1/2” H42DLN (NG ONLY) Hearth Wall Figure 18. H34DL*, H38DL*, or H42DLN Straight run, Rear Vented, wall mounted termination. The vent run must comply with the Venting Graph for Rear vent, wall mounted terminations, Figures 15, 16 or 17.
  • Page 15: Rear Vent, Wall Mounted Termination (45° Corner)

    H-Series DL Gas Fireplace Installation 45° Corner Installation. Attach an EEL-45 / PEL-45 (45° elbow) directly onto the flue collar. Cut the MXT-20 / PXT-20 to suit, and attach it to the EEL-45 / PEL- 45. Slide the fireplace into position and attach to the termination. 100 or 101 Rigid Section Rigid Elbow...
  • Page 16: Section 3-3-2: Venting Components

    PEXT - 2 (24" f/m Section) MEXT - 3 (36" f/m Section) PEXT - 3 (36" f/m Section) Montigo recommends the use of a flex section for the final pipe „ MEXT - 4 (48" f/m Section) PEXT - 4 (48" f/m Section) connected directly to the fireplace offering greater flexibility of MEXT - 6 (72"...
  • Page 17: Section 3-3-3: Heat Shields

    Next, slide the RHS100/RHS101 outer section from the outside of the installed, clearances should match the dimensions in Figure 20. structure, see Figure 21. Note: RHS7 is for H34DL* models only. RHS8 is for H38DL* and H42DL* To complete the installation fasten the Heat Shield Outer Section & models only.
  • Page 18: Section 4: Wiring

    H-Series DL Indoor Gas Fireplace Installation Section 4: Wiring Models H34DLNI-F H34DLL-F ON / OFF H38DLN-F H38DLL-F Green (CPI / IPI MODE Orange Not Used) H42DLN-F H42DLL-F IPI/CPI ON/OFF Battery Holder 4 x 1.5V AA Type Black 880 Valve VALVE BATTERY Chassis 120 Vac INPUT...
  • Page 19: Installing Remote On/Off Wall Switch

    H-Series DL Gas Fireplace Installation Installing the remote On/Off Wall Switch The H*DL* gas valve may be connected to a wall switch. Do NOT connect any external power to the remote switch. The valve will generate its own power on a millivolt circuit or will draw its power from an AC Connection inside the fireplace, depending on the model of the unit.
  • Page 20: Installing The Gas Line

    1/8” N.PT. plug to be fitted with a hose barb. follow the appropriate local codes or your area. DO NOT connect Montigo requires a service shut off valve be located in an „ the fireplace to pressures in excess of 1/2lb. This will damage the accessible location to isolate the gas supply.
  • Page 21: Finishing

    H-Series DL Gas Fireplace Installation Finishing Around the Fireplace WARNING! Combustible mantels and mouldings may be safely installed over the top and on the front of the fireplace provided that they do not project We recommend careful consideration be given to the effects of beyond shaded area shown in Figure 27.
  • Page 22: Installing And Removing The Door

    H-Series DL Indoor Gas Fireplace Installation Removing the door: The H*DL* Series door is removed in a few simple steps. Follow these Step 5: instructions below to remove the Horizontal access panel, unlatch the Ensure the tool is firmly door buckles and, remove the door. Replace in reverse order. in the lower end of the slot, (as shown), Then pull toward you (Caution: hold...
  • Page 23: Section 8: Installing The Accessories

    Installation Section 8: Installing the Accessories Installing the Logs: Top Left Log The H34DL* is supplied with five ceramic fibre logs. Unpack the logs and handle them very carefully. Remove the glass door as described on Page 22. Notch Fireplace Base...
  • Page 24: Installing The H38Dl & H42Dl Log Set

    H-Series DL Indoor Gas Fireplace Installation Installing the Logs: The H38DL* and H42DL* is supplied with a seven ceramic fibre log Right Log logset. Unpack the logs and handle them very carefully. Left Log Align Pins Step 1. Remove the glass door as described on Page 22. Align Pins Rear / Bottom Log Notch in Log...
  • Page 25: Installing The Top / Bottom Horizontal Louvers

    H-Series DL Gas Fireplace Installation Installing the Horizontal Louvres: Ensure the fireplace is turned off before beginning installation. Place Embers in this area Install the upper louvre assembly as shown in figure 31a. Before tightening the screws fully, adjust the louvre assembly so that it is centred horizontally and vertically.
  • Page 26: Operation

    H-Series DL Indoor Gas Fireplace Operation Section 9: Start-up Sequence Standing (Continuous) Pilot Ignition (SIT NOVA 820) with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: NOTICE You must read and understand this manual prior to installation, operation or troubleshooting this appliance.
  • Page 27: Start-Up Sequence Sit Prolame Gas Valve

    H-Series DL Indoor Gas Fireplace Operation IPI Electronic Ignition (SIT Proflame) with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: NOTICE You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for furure reference and maintenance.
  • Page 28: Start-Up Sequence With Honeywell Electronic Ignition

    H-Series DL Indoor Gas Fireplace Operation Honeywell Electronic Ignition For Your Safety - READ BEFORE LIGHTING: NOTICE You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for furure reference and maintenance.
  • Page 29: Maintenance

    H-Series DL Indoor Gas Fireplace Maintenance Lighting Instructions Hi-Lo Burner Adjustment: (SIT Nova 820). See pages 26 to 28. The H*DL* is equipped with an adjustable burner, allowing you to raise or lower the flames. To adjust the flames, locate the black knob marked General 'Hi-Lo', in the centre of the gas control valve (See Figure 32).
  • Page 30: Troubleshooting

    If your fireplace still does not operate correctly, consult your local Montigo dealer. All service and repairs should be performed by a qualified Technician. All spare parts, optional fans, and optional trim finishes are available from your local Montigo dealer. Page 30...
  • Page 31: Parts List

    RLGSH34 RLGSH38 RLGSH42 Log Base RLGSH34B RLGSH38B RLGSH42B All service and repairs should be performed by a qualified Technician. All spare parts, optional fans, and optional trim finishes are available from your local Montigo dealer. Page 31 XG0140 - 120611.1...
  • Page 32: Appendix

    H-Series Indoor Gas Fireplace Appendix Appendix A: Termination Locations Location Canada* USA** clearance to the termination frame above grade, veranda, porch, deck, or balcony 12 inches 12 inches clearance to top of doors or operable windows 12 inches 12 inches 9 inches 12 inches clearance to sides or bottom of door or operable windows...
  • Page 33: Warranty

    The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
  • Page 34: State Of Massachusetts

    H-Series Indoor Gas Fireplace Appendix Appendix C: State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by adding the following additional requirements:...
  • Page 35: Mobile Home

    H-Series Indoor Gas Fireplace Appendix Appendix D: HC34DLM Mobile Home HC34DLM-Mobile Home fireplaces: Gas Control Valve The mobile home option is factory installed on the HC34DLM gas The following gas control valve is installed on the HC34DLM. fireplaces, and are for use in a manufactured or mobile home. Power 'Hi-Lo' Adjustment Knob Pilot Adjustment Screw...
  • Page 36 H-Series Residential Gas Fireplace Ferndale, Washington Langley, British Columbia TF: 1.800.789.6236 TF: 1.800.378.3115 FX: 1.866.3000.0927 FX: 1.604.607.6462 XG0140 - 120611.1...

Table of Contents