Chapter 5 Creating Your Own Patterns and
Modifying Performance Data
Values
Changes existing data settings.
Procedure
1. Press the [PTN] button.
2. Using the [VALUE] dial or the [INC/DEC] buttons,
select the pattern for which you want to edit.
3. Press the [F3 (EDIT] button.
The "PATTERN EDIT" screen appears.
4. Press the [F3 (MICRO SCOPE)] button.
The "MICROSCOPE" screen appears.
5. Use the [CURSOR (up/down)] buttons to select the data
whose setting is to be modified.
6. Use the [CURSOR (left/right)] buttons to move the
cursor to a setting as shown below.
7. Change a value using the [VALUE] dial or the [INC/
DEC] buttons.
Inserting Musical Data
(Insert Event)
Specify the position at which you want to insert data and
select the type of data to add.
Procedure
Invoke the microscope screen.
1. Press the [PTN] button.
2. Using the [VALUE] dial or the [INC/DEC] buttons,
select the pattern for which you want to edit.
3. Press the [F3 (EDIT] button.
The "PATTERN EDIT" screen appears.
4. Press the [F3 (MICROSCOPE)] button.
The "MICROSCOPE" screen appears.
Specify the position at which data is to be inserted.
5. Pressing the [CURSOR (left/right)] buttons, position the
cursor at the measure, beat or clock.
74
6. Determine the insertion position using the [VALUE] dial
or the [INC/DEC] buttons.
Insert the data.
7. Press the [F1 (INS)] button.
The screen for selecting the types of data to be inserted
appears.
Example1: R, 1 - 7 Part
Example2: MUTE CTRL part
8. Select the type of data using the [VALUE] dial or the
[INC/DEC] buttons.
* For the types of data you can enter, see "Setting Range" at the
end of this section.
9. Upon selection, press the [F4 (OK)] button.
* When you have selected SYS-EX (System Exclusive), the
following message appears. Using the same procedure as the
one for Change Event, enter hexadecimal numbers by pressing
the keyboard pad and [ENTER] button in turn.
Available Settings:
When the microscope is in the range from [R], [1] to [7]:
- NOTE:
Note
- PC:
Program Change
- CC:
Control Change
- BEND:
Pitch Bend
- P-AFT:
Polyphonic Aftertouch
- C-AFT:
Channel Aftertouch
- When the microscope is MUTE CTRL:
When the microscope is in the "MUTE CTRL:"
- SYS-EX: System exclusive
- TEMPO: Tempo change message
- MUTE: Mute message