Local Tx Sw - Roland Groovebox MC-307 Reference Manual

Hide thumbs Also See for Groovebox MC-307:
Table of Contents

Advertisement

Chapter 7 Environment Configuration and
Disconnecting the keyboard pads from
the internal sound generator

(LOCAL TX SW)

You can specify how MIDI messages from the controller
section (the keyboard pad, knobs, pedals etc.) will be sent to
each part [R], [1] to [7]. Use [PART SELECT] button and the
PART buttons to select the part whose settings you wish to
modify.
Procedure
1. Press the [SYSTEM] button, then the [F1 (SYS)] button.
The selection screen for system settings appears.
2. Press the [CURSOR (up)] button to access the screen for
items 1–4.
3. Press the [F4 (MIDI)] button.
4. Press the [F2 (TXRX)] button.
If the following screen is not displayed, use [F3 (
(
)] to make it appear.
5. Press [PART SELECT] button.
6. Press the part button, [R], [1] to [7], for the part for which
the parameter is to be set up.
7. Specify a value using the [VALUE] dial or the [INC/
DEC] buttons.
The listing at the bottom of the display shows the
settings for the respective parts. Parts R and 1 to 7 are
listed from left to right in sequence, and "I" indicates
transmission to the internal sound generator only while
"E" indicates transmission to MIDI OUT only.
Available Settings:
- INT (I):
Messages from the controller section will be
transmitted only to the internal sound generator.
- EXT (E): Messages from the controller section will be
transmitted only to MIDI OUT.
- BOTH (B):Messages from the controller section will be
transmitted both to the internal sound generator and to
MIDI OUT.
Parameter Type: Backup parameters
126
Reception settings for each type of
MIDI message
Procedure
1. Press the [SYSTEM] button, then the [F1 (SYS)] button.
The selection screen for system settings appears.
2. Press the [CURSOR (up)] button to access the screen for
items 1–4.
3. Press the [F4 (MIDI)] button.
4. Press the [F2 (TXRX)] button.
If the following screen is not displayed, use [F3 (
(
)] to make it appear.
5. Use the [CURSOR (up/down)] buttons to move the
cursor to "RX. PROG CHANGE," "RX. BANK SELECT"
or "RX. SYSEX."
)][F4
6. Specify a value using the [VALUE] dial or the [INC/
DEC] buttons.
Available Settings:
- RX.PROG CHANGE (Receive Program Change Switch)
Specifies whether or not each part will receive program
changes. When this is "OFF," program changes will not
be received.
Range: OFF, ON
- RX.BANK SELECT (Receive Bank Select Switch)
Specifies whether or not each part will receive bank
select messages. When this is "OFF," bank select
messages will not be received.
Range: OFF, ON
- RX.SYSEX (Receive System Exclusive Switch)
Specifies whether or not each part will receive system
exclusive messages. When this setting is "OFF," system
exclusive messages will not be received.
Range: OFF, ON
Parameter Type: Backup parameters
)][F4

Advertisement

Table of Contents
loading

Table of Contents