Function Flowm Test; Function Ext.board Test - Rancilio EGRO 5511 Technical Manual

Hide thumbs Also See for EGRO 5511:
Table of Contents

Advertisement

EGRO 5511 Manual

5.7 Function FLOWM TEST

Function: Check the Flowmeter
Start/Stop:
Display: Continuous display of FM signal.
100 FM-Imp. = ca. 1/2 dl.

5.8 Function EXT.BOARD TEST

5.8.1
24V OUTPUTS.
Function: Check the 8 (24VDC) outputs on
the extension card
Selection: +/-
Start/Stop: ↓
Status:
1 = Component activated
0 = Component not activated
Display
Component
MP 1
0
Milk pump M4 (left milk outlet / foam)
MP 2
0
Milk pump M5 (right milk outlet / milk)
CWV
0
Cold water valve for automatic milk rinse
SV
0
Steam valve for automatic milk rinse
ABV
0
Air bleed valve for automatic milk rinse
AFV
0
Air foaming head valve
RES(2,3)
0
Spares
5.8.2
SIGNAL INPUTS..
24V OUTPUTS..( press + button)
Function: Check the 8 (24VDC) inputs on
the extension card (Print ok)
Status:
1 = signal active
0 = signal not active
Flowmeter P1 (coffee)
0 0 99
Component
MP1
0
Jack on ex-
tension card
Statusanzeige
0 0 0 0 1 1 0 0
Bohnensensor
Status
LED
(red)
J46 / 1-2
3
J46 / 3-4
4
J45 / 12-11
10
J45 / 10-9
9
J45 / 8-7
8
J45 / 5-6
7
J45 / 4-1
6, 5
Milchsensor
Page 34

Hide quick links:

Advertisement

Table of Contents
loading