EGRO 5511 Manual
5.5 Function LEVEL TEST
Function:
Checks the water level sensor
in the steam boiler
Components: Level sensor B3 (J11/5)
Status:
B3 = 1 below water level
(level o.k.)
B3 = 0 above water level
(level too low)
5.6 Function POS-SW TEST
Function: Activates the end switches
Procedure: First bring the component into the
position where the sensor is active
(see following table)
Activate the function
Check the switch signal
Switch
Component Type
Pressure switch for steam
1
boiler
Microswitch for grounds
2
drawer
LEVEL
B3
1:1
Status
Jack on con-
Position for Status = 1
trol card
0 = Temperature reached
J9/6-7
1 = Pressure switch closed
(Pressure too low)
1 = Drawer is in place
J15/1-2
0 = Cover is open
Component
1
Status
Component
2:1
Page 33