DRAIN LINE CONNECTION

1. 1.
Remove the right-side panel of the
Egro 5511.
To do this, remove the two screws on top
of the machine (
). Lift the right-side
P4
panel straight up to remove it.
2. 2.
Locate the brew valve solenoid on the
back-right side of the machine. (
Attach the provided silicon tubing to the
bottom of the brew valve and route it
down through the hole in the bottom panel
of the Egro 5511 (
).
P6
Make sure the silicon tubing is firmly attached
to the bottom of the brew valve. During the
cleaning cycle pressure will increase, which
can cause the tubing to become disconnected
if it is not properly and securely attached.
3. 3.
Locate the drain hose provided.
Cut a 4" piece from the hose using a utility
knife, and attach it to the barbed drain tray
fitting under the Egro 5511 (
4. 4.
Locate the plastic T-fitting provided (
· Attach the silicone tubing to the small connec-
tor of the T-fitting.
· Attach one of the large T-fitting connectors to
the 4" piece of drain hose.
· Attach the remaining drain hose to the other
large T-fitting connector (
· Then route the drain hose from down to the
floor drain in a continuous downward slope.
The floor drain must be at least 30mm (1.2") in
diameter.
5. 5.
Replace the right-side panel.
).
P5
).
P7
).
P8
).
P9
P
4
Side view with panel removed, brew valve solenoid circled
P
5
P
6
P
7
P
8
P
9
Top right
view, with
two screws
circled
Brew valve solenoid,
with silicon tubing
firmly attached
Underneath
machine, with
4" drain hose
piece attached
to drain tray
fitting
Plastic
T-fitting
Finished drain
line connection
Page 12