Submenu Monitor; Function Valve Test - Rancilio EGRO 5511 Technical Manual

Hide thumbs Also See for EGRO 5511:
Table of Contents

Advertisement

EGRO 5511 Manual
5

SUBMENU MONITOR

Monitor functions allow various machine components to be checked. No test can check com-
pletely the entire functionality of any component. In addition during error testing, the me-
chanical soundness of the component must be confirmed.

5.1 Function VALVE TEST

Function: Functioning of valves, testing the
electrical connections
Selection: +/-
Start/Stop: ↓
Status:
1 = valve active
0 = valve idle
Display
BV
Y1
TEA
Y2
ST-FILL
Y3
CAP
Y4
RES1
Y5
RES2
Y6
The automatic heating is switched off in the monitor programme!
PLEASE NOTE:
Restart the machine after using the monitor section.
Component
0
Brewing valve
0
Hot water (tea valve) / Steam added
0
Steam boiler refill valve
0
Steam valve for Cappuccino
0
Spare (Cappuccino right)
0
Spare
Component
BV
Y1
0
Jack on con-
trol card
J10/ 1-2
J10/3-4/5-6
J10/7-8
J10/9-10
J10/11-12
J10/13-14
Status
LED
(red)
9
10
11
12
13
14