"A" Group: Standard Functions
Run Command Source Setting - For parameter A002, the following table provides a
further description of each option, and a reference to other page(s) for more information
Code
01
02
03
A001/A002 Override Sources - The inverter allows some sources to override the
settings for output frequency and the Run command in A001 and A002. This provides
flexibility for applications that occasionally need to use a different source, leaving the
standard settings in A001/A002. In particular, note the TM/PRG (Terminal/Program)
DIP switch behind the front panel cover shown below. It is the switch to the right.
The TM/PRG switch setting forces terminal operation, according to the table below:
TM/PRG
Switch Position
PRG (Program)
TM (Terminal)
When A001 = 01 and A002 = 01, the inverter control source is the terminals, regardless
of the TM/PRG switch position. When A001 and A002 setting is not 01, then the
TM/PRG switch can force terminal input control.
Run Command Source
Control terminal - The [FW] or [RV] input terminals control
Run/Stop operation
Keypad Run key - The Run and Stop keys provide control
ModBus network input - The network has a dedicated coil
for Run/ Stop command and a coil for FW/RV
Output frequency source
Run command source
Output frequency source
Run command source
Item
Specified by A001 setting
Specified by A002 setting
[O] or [OI] analog input terminal
[FW] and/or [RV] input terminals
Refer to page(s)...
4–12
3–47
,
2–25
B–19
SR
485
TM
SK
OPE
PRG
Source