Hitachi SJ2002 Series Instruction Manual page 128

Hide thumbs Also See for SJ2002 Series:
Table of Contents

Advertisement

3–48
"C" Group: Intelligent Terminal Functions
Input Function Summary Table – This table shows all twenty-four intelligent input
functions at a glance. Detailed descriptions of these functions, related parameters and
settings, and example wiring diagrams are in
page
4–9.
Option
Terminal
Code
Symbol
00
FW
01
RV
02
CF1 *1
03
CF2
04
CF3
05
CF4
06
JG
07
DB
08
SET
09
2CH
11
FRS
Input Function Summary Table
Function Name
Forward Run/Stop
ON
OFF
Reverse Run/Stop
ON
OFF
Multi-speed Select,
ON
Bit 0 (LSB)
OFF
Multi-speed Select,
ON
Bit 1
OFF
Multi-speed Select,
ON
Bit 2
OFF
Multi-speed Select,
ON
Bit 3 (MSB)
OFF
Jogging
ON
OFF
External DC Braking ON
OFF
Set (select) 2nd
ON
Motor Data
OFF
2-stage Acceleration
ON
and Deceleration
OFF
Free-run Stop
ON
OFF
"Using Intelligent Input Terminals" on
Description
Inverter is in Run Mode, motor runs forward
Inverter is in Stop Mode, motor stops
Inverter is in Run Mode, motor runs reverse
Inverter is in Stop Mode, motor stops
Binary encoded speed select, Bit 0, logical 1
Binary encoded speed select, Bit 0, logical 0
Binary encoded speed select, Bit 1, logical 1
Binary encoded speed select, Bit 1, logical 0
Binary encoded speed select, Bit 2, logical 1
Binary encoded speed select, Bit 2, logical 0
Binary encoded speed select, Bit 3, logical 1
Binary encoded speed select, Bit 3, logical 0
Inverter is in Run Mode, output to motor runs at
jog parameter frequency
Inverter is in Stop Mode
DC braking will be applied during deceleration
DC braking will not be applied
The inverter uses 2nd motor parameters for
generating frequency output to motor. The selec-
tion of 1st or 2nd motor is available only during
Stop Mode.
The inverter uses 1st (main) motor parameters
for generating frequency output to motor
Frequency output uses 2nd-stage acceleration
and deceleration values
Frequency output uses standard acceleration and
deceleration values
Causes output to turn OFF, allowing motor to
free run (coast) to stop
Output operates normally, so controlled deceler-
ation stops motor

Advertisement

Table of Contents
loading

Table of Contents