Func.
Name
Code
A152 Pot. input active range
end frequency
A153 Pot. input active range
start current
A154 Pot. input active range
end current
A155 Pot. input start
frequency enable
Note 1:
When the value is 10000 (100.0 seconds), a value in the second decimal place
is ignored (for A092/A292 and A093/A293).
Holding Registers for "A" Group Standard Functions
R/W
Description
R/W The output frequency corre-
sponding to the potentiometer
range ending point,
range is 0.0 to 400.0
R/W The output frequency corre-
sponding to the potentiometer
range starting point,
range is 0 to 100
R/W The output frequency corre-
sponding to the potentiometer
range ending point,
range is 0 to 100
R/W Two options:
00 ...Disable
01 ...Enable
SJ200
Inverter
2
Network Data
Register
Range
hex
dec.
1097h
4247
0 to 4000
1098h
4248
0 to 100
1099h
4249
0 to 100
109Ah
4250
0, 1
B–33
Res.
0.1 Hz
1%
1%
—