3 – Event Messages
Alarm Events
(A2001.0003) (blade_id) (Blade fault (SENSOR_FAULT) - CLEARED)
Meaning:
Action:
(A2001.0004) (blade_id) (Blade fault (AC_FAULT) - ALARM CLEARED)
Meaning:
Action:
(A2002.0001) (fan_number was removed)
Meaning:
Action:
(A2002.0002) (Fan fan_blade failure - ALARM SET)
Meaning:
Action:
(A2002.0003) (Fan or power supply flow mismatch - ALARM SET)
Meaning:
Action:
(A2003.0001) (fan_blade inserted - ALARM CLEARED)
Meaning:
Action:
(A2003.0002) (fan_blade OK - ALARM CLEARED)
Meaning:
Action:
(A2003.0003) (Fan flow match - ALARM CLEARED)
Meaning:
Action:
(A2004.0001) (Secondary cpu_blade assuming control of system due to a failure of Primary
cpu_blade)
Meaning:
Action:
3-42
The internal fault on the specified Power Supply blade has been
cleared.
None
The specified Power Supply blade is receiving power.
None
A field replaceable fan was removed from the switch.
Reinstall the fan.
A cooling fan has failed.
Replace the fan if it is a customer replaceable unit. Otherwise,
contact your authorized maintenance provider.
The switch has two cooling fans with opposite air flow directions.
Replace one of the fans with another fan with the correct air flow
direction.
The switch fan blade has been installed and the alarm is cleared.
None
The switch fan blade is operational and the alarm is cleared.
None
The opposing fan air flow condition has been corrected.
None
Control is transferring from the primary CPU blade to the
secondary CPU blade on a SANbox 9000 switch.
Investigate the former primary CPU blade for the cause of the
failure.