Qlogic Fibre Channel Switch Event Message Manual page 40

Firmware version 7.4/7.8
Hide thumbs Also See for Fibre Channel Switch:
Table of Contents

Advertisement

3 – Event Messages
Alarm Events
(A1005.0066) (Switch is not fault-tolerant. Fault Tolerant license is installed, but secondary
CPU is faulted)
Meaning:
Action:
(A1005.0067) (HyperStack(tm) license installed, but only 1 CPU blade installed - alarm
status)
Meaning:
Action:
(A1005.0068) (Primary blade seating is questionable)
Meaning:
Action:
(A1005.0069) (Primary blade seating was resolved)
Meaning:
Action:
(A1005.006A) (User account account_name has expired)
Meaning:
Action:
(A1005.006B) (Temperature too high, turning off lasers)
Meaning:
Action:
(A1005.006C) (3.3V out of spec, turning off lasers)
Meaning:
Action:
3-28
The SANbox 9000 switch is not fault tolerant because of a fault on
the secondary CPU blade.
Replace the secondary CPU blade.
A SANbox 9000 switch that is licensed for HyperStacking must
have two CPU blades to make use of the HyperStack feature. If
only one CPU blade is installed, this alarm message is issued with
alarm status ALARM SET. When the second CPU blade is
installed, the alarm message is reissued with alarm status ALARM
CLEAR.
If the alarm status is ALARM SET, install the second CPU blade.
The SANbox 9000 primary CPU blade is not fully installed.
Reseat the primary CPU blade.
The SANbox 9000 primary CPU blade seating problem has been
corrected.
None
The named user account has exceeded its expiration date.
Review the user account and make the necessary corrections.
The switch has overheated and the Fibre Channel port lasers have
been turned off.
Power down the switch, correct the conditions that caused the
switch to overheat, and power up the switch.
Fibre Channel switch ports are receiving incorrect voltages. Lasers
have been turned off.
Contact your authorized maintenance provider.
S
59060-06 A

Advertisement

Table of Contents
loading