Qlogic Fibre Channel Switch Event Message Manual page 29

Firmware version 7.4/7.8
Hide thumbs Also See for Fibre Channel Switch:
Table of Contents

Advertisement

A
(A1004.0026) (Configured Domain ID domain_ID not available and Domain ID is locked on
this switch)
Meaning:
Action:
(A1004.0029) (No Switch capable of being Principal Switch. Reconfigure Principal Switch
Priority.)
Meaning:
Action:
(A1004.002B) (Port port_number not configured for E-Port capability, reconfigure to G/GL
to connect to remote switch)
Meaning:
Action:
(A1004.002D) (Non-interop Legacy switch setting prevents domain/port zoning)
Meaning:
Action:
(A1004.002F) (Request for Domain ID rejected, WorldWide Name (WWN) device_WWN not
allowed to join fabric.)
Meaning:
Action:
(A1004.0030) (Topology change, lost route to switch with domain ID domain_ID)
Meaning:
Action:
59060-06 A
An attempt was made to connect a switch to a fabric with a
conflicting domain ID, and the domain ID could not be reassigned.
Change the domain ID so that it is unique in the fabric, or disable
the domain ID lock so that the domain ID can be automatically
reassigned.
An E_Port isolated because the principal priority on all switches is
set to 254.
Configure one of the switches to be the principal switch by
changing the principal priority.
An attempt was made by a remote switch to connect through a port
that could not configure itself as an E_Port.
Change the port type on the remote switch to G_Port or GL_Port.
Zone members involving switches of other vendors cannot be
defined by domain ID and port number when Interop Mode is
disabled and Legacy Address Formatting is enabled.
Disable (False) the Legacy Address Formatting, enable Interop
Mode, or reassign the zone members using a method other than
domain ID and port number.
The switch with the specified worldwide name is not allowed to join
the fabric.
Add the switch to a group in the active security set.
Connection to a switch in the fabric was lost.
Inspect switch connections and device hardware for proper
operation. Review accompanying alarms for other causes.
3 – Event Messages
Alarm Events
3-17

Advertisement

Table of Contents
loading

Table of Contents