Over Temperature Blink Pattern - Qlogic SANbox 5600 Series Installation Manual

Fibre channel switch
Hide thumbs Also See for SANbox 5600 Series:
Table of Contents

Advertisement

5 – Diagnostics/Troubleshooting
Power-On Self Test Diagnostics
e.
f.
g.
h.
5.2.1.4

Over Temperature Blink Pattern

An over temperature blink pattern is 5 blinks followed by a two second pause. The
5-blink error pattern indicates that the air temperature inside the switch has
exceeded the failure temperature threshold. The failure temperature threshold is
70° C.
If the Heartbeat LED shows the over temperature blink pattern, do the following:
1.
Inspect the chassis vents. Are the intake and exhaust vents clear?
2.
For a model 5602 switch, inspect the Power Supply Fault LED on both
power supplies; otherwise continue. Is the Power Supply Fault LED
illuminated on either power supply?
5-6
Establish communications with the switch using Telnet. Enter one of
the following on the command line:
telnet xxx.xxx.xxx.xxx
or
telnet switchname
where xxx.xxx.xxx.xxx is the switch IP address and switchname is the
switch name associated with the IP address.
A Telnet window opens prompting you for a login. Enter an account
name and password. The default account name and password are
(admin, password).
Open an admin session to acquire the necessary authority.
SANbox $>admin start
Restore the configuration file. When the restore is complete, the switch
will reset.
SANbox (admin) $>config restore
2 seconds
Yes - Continue.
No - Remove any debris from fan intake and exhaust if necessary. If
the condition remains, continue.
Yes - Replace the power supply. If the condition remains, continue.
No - Continue.
S
59096-02 C