Dell Networking 7048 Release Note page 63

5.1.0.1 firmware release notes
Hide thumbs Also See for Networking 7048:
Table of Contents

Advertisement

PowerConnect 8132/8164/8132F/8164F/8024/8024F/M8024/M8024-k/
M6220/M6348/7024/7048/7024P/7048P/7024F/7048R/7048R-RA
Release Notes
Summary
User Impact
Port goes down if the
If the port is operating in Trunk mode and UDLD
port is excluded from
is enabled, the port goes down if it is excluded
native vlan with UDLD
from the native vlan.
feature enabled on it.
SNMP V3 walk may fail
After failover, SNMP V3 walk may fail, as MIB
after "initiate failover"
browser and agent can become out of time and
command is issued.
stop intercommunication.
OOB static IP entry
After receiving an IP address from the DHCP
cannot be the same as the
server, the switch gives an error and will not
DHCP assigned IP
allow an attempt to add a static IP address and
address
gateway that is the same as the DHCP IP address.
Release 4.2.2.3
Summary
User Impact
Stack member units port
Wrong id for the power LED is displayed.
display is missing in
web GUI.
WebUI sFlow Polling
sFlow>Sampler configuration and sFlow>Poll
page issues.
Configuration don't work for ports Gig1/0/1 -
1/0/9.
Release 4.2.1.3
Summary
User Impact
"show interfaces
Some general mode VLANs tagged to the
switchport " command
interface may not be displayed using this
shows incorrect General
command.
Mode Tagged VLANs
value
M6220 OOB interface
On a failover on a M6220 stack the OOB
unreachable after
interface may not be available.
failover
CLI command "show ip
"show ip dhcp snooping binding" not displaying
dhcp snooping binding"
client information. "show ip dhcp snooping
not displaying client
statistics" does not display correct message
information.
counts.
OOB interface
The setup wizard does not honor selection to not
configured with default
setup OOB IP address.
IP via Setup Wizard
though told not to do so.
DHCPv6 - M6220,
By looking at the counters, the client believes it
PC/M 8024/k - Client
is sending solicits; but, the relay and the server
Solicits do Not Seem to
never see the solicitations.
Make it to the Server /
Relay
Release 4.2.0.4
Summary
User Impact
File modification date &
When internal files are modified, they do not get
time is not getting
the current time stamp.
updated with current
time & date.
System Firmware Version 5.1.0.1
Workaround
Include the port in native vlan.
After a failover, close the browser and re-open
it. SNMPv2 works correctly.
Use a different IP address than the DHCP
address given.
Workaround
None
None
Workaround
Use "show vlan" command to interfaces. No
other workaround.
Recovers when the master is restored.
None
OOB IP address will need to be setup
manually.
None
Workaround
None
Page 61

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents