Dell Networking 7048 Release Note page 34

5.1.0.1 firmware release notes
Hide thumbs Also See for Networking 7048:
Table of Contents

Advertisement

CLI command
CLI command "show dot1x users" is
"show dot1x
missing
users" is missing
Missing port
Changing VLAN configuration for general
membership
mode affected trunk mode configuration
from SNMP
and there from the port membership
(dot1qVlanStati
returned via SNMP.
cUntaggedPorts
and
dot1qVlanStatic
EgressPorts)
The VRPP track
The VRRP track port priority in the running
port priority
config is retrieving the operational value
changes in the
instead of the configured value.
running config
Firmware won't
The hyphen is part of the allowed characters
allow domain
available for the email address.
names with
hyphen "-" in
logging email
Internal ports
Internal ports were up while switch is
are up during
booting, this was causing traffic loss in
most of the
network.
switch POST
Continuous log
POE log message comes up during power
message at
up sometimes.
default settings
DNS client error
The meaning of the DNS error message:
"DNS Client: osapiSocketRecvFrom
returned error for addr 0x1214BCA8" is
unclear.
VRRP
Ping to a remote host will not work if
Intermittent
switch acts as VRRP master
Connectivity
Issues
VLAN
VLAN membership port names are not
membership
consistent.
port names not
consistent in
GUI
Radius crash
Sometimes switch crashes when receiving
of Radius packets
In a Stack, the
CLI output for command "show system
"show system
temperature" is corrupted when
temperature"
pagination is used because the stack
CLI command
displays much more data.
breaks CLI
QOS on port
There is no way to see the match packet
channel
counts of a policy-map on a port-channel.
32
Corrected the command tree
for the "show dot1x users"
command.
Corrected the issue.
Corrected the retrieval of the
configured value
Added the hyphen to the
allowed characters for email
addresses.
Corrected the initialization of
the internal ports. CPLD Code
Update is required.
1. Update the CPLD using the
command 'dev cpldUpdate'
Console#dev cpldUpdate
2. Power cycle the switch.
(Power Cycle from CMC
WebUI. Do not run "reload"
from the console prompt)
Removed unwanted message.
Corrected the text of the
message.
Corrected a VRRP
communication issue.
Corrected the port numbers
displayed in the GUI.
Corrected the crash.
Corrected the pagination issue.
Command "show policy-map
interface port-channel <port-
channel number>" was added.
System Firmware Version 5.1.0.1
All 4.2 supported
platforms
All 4.2 supported
platforms
All 4.2 supported
platforms
All 4.2 supported
platforms
PCM8024-K
PC7024P/PC7048P
All 4.2 supported
platforms
All 4.2 supported
platforms
All 4.2 supported
platforms
All 4.2 supported
platforms
All 4.2 supported
platforms
All 4.2 supported
platforms

Hide quick links:

Advertisement

Table of Contents
loading