Clean the reading glass and rollers frequently to ensure the quality of transmitted
images and copies. Open the operation panel by pulling the front edge up (grasp it
at the "PANEL RELEASE" mark), and clean them as shown below.
Wipe the reading glass, white backplate,
4
and rollers with a soft cloth or cotton
swab.
Make sure that all dirt and stains (such
as correcting fluid) are removed, as
these will cause vertical lines on
transmitted images and copies.
Adhesive cellophane tape is useful for
removal of debris from the rollers.
Document
I
White backplate
rollers
Reading glass
Wipe the external
parts
and surface of the machine with a dry cloth,
Caution!
Do not use benzene or thinner. These solvents may damage or discolour the
machine.