View The System Power Status; View Processor Board Information - Intergraph InterServe 8000 Setup Manual

Hide thumbs Also See for InterServe 8000:
Table of Contents

Advertisement

CPU 1: status (System Off, Absent, X.XXV Okay, or X.XXV FAIL)
Nominal CPU 1: x.xV
CPU 2: status (System Off, Absent, X.XXV Okay, or X.XXV FAIL)
Nominal CPU 2: x.xV
CPU 3: status (System Off, Absent, X.XXV Okay, or X.XXV FAIL)
Nominal CPU 3: x.xV
The above items correspond to the following system components:
u
Power supplies: +3.3V, +5Unsw, +5.0V, -5.0V, +12.0V, -12.0V
u
Processor board: GTL 0, GTL 1
u
Voltage regulator modules: CPU 0, Nominal CPU 0, CPU 1, Nominal CPU 1, CPU 2,
Nominal CPU 2, CPU 3, Nominal CPU 3
If any of the voltage items show a failure, then the corresponding component may need to be
replaced. For example, if GTL 1: FAIL is displayed, then the processor board needs to be
replaced. Call the Customer Response Center at 1-800-633-7248 if any of the voltage items
show a failure.

View the System Power Status

Path: System Status > Sys. Power
Sys. Power: status displays On, Offloc, or OffRmt. OffLoc shows the system was shut
down from the keyboard and powered off from the keyswitch. OffRmt shows that the
system was shut down and powered off by remote command via the InterSite Server Monitor.
Press
ESCAPE

View Processor Board Information

Path: System Config. > Processor Board
The installed processor board number (MSMT329xx), its engineering change level
(ECO xx), and serial number display. Press
processor board components (processors, memory, and SIMM sockets), as described in the
next three sections.
NOTE
The
Serial#
to return to the previous menu.
line does not display if the board does not have a valid serial number.
to display information about the
ENTER
61

Advertisement

Table of Contents