View the Internal Temperatures or Change the Temperature Scale

Path: System Status > Temperature
Temperature: status displays a general indication of system temperature. When all
sensors detect normal temperatures, this line displays Okay. If Wm or HOT displays, one or
more of the internal sensors is reporting a problem. Press
option to display the specific status for the sensors:
Ambient: value status (Ok, Wm, or HOT)
Sensor1: value status (Ok, Wm, or HOT)
Sensor2: value status (Ok, Wm, or HOT)
Sensor3: value status (Ok, Wm, or HOT)
Sensor4: value status (Ok, Wm, or HOT)
Scale: value (Fahrenheit or Celsius)
The temperature displays for each of the system's four sensors. Normal temperatures are
indicated by Ok. The following table states the warm and hot (unsafe) temperatures for the
sensors.
Sensor
Ambient
Sensor1
Sensor2
Sensor3
Sensor4
CAUTION
Temperatures that are approaching the unsafe levels are indicated by
reports a
Wm
fans are working. If room temperature is less than 80 degrees Fahrenheit and the fans are
spinning, the fan speed may be too slow. Call the Customer Response Center at
1-800-633-7248.
WARNING If a sensor reports
could damage internal components. If the cause of the hot temperature condition is
not related to the room environment, call the Intergraph Customer Response Center.
NOTE
The threshold for the Ambient sensor can be changed. Refer to "Change the Ambient Heat
Threshold" later in this chapter. The thresholds for the internal sensors cannot be changed.
Location
Next to drive access door (room air
temperature)
Between the processors and the power
distribution board
Between the memory modules, near the
rear air vent
At the middle of I/O expansion board
Next to ISA slot 4
status should be monitored closely. Adjust room temperature and ensure the
HOT
, power off the system to protect it from overheating, which
at the TEMPERATURE
ENTER
Warm (Wm)
Hot (Hot)
32 C (90 F)
35 C (95 F)
42 C (108 F)
45 C (113 F)
42 C (108 F)
45 C (113 F)
42 C (108 F)
45 C (113 F)
47 C (117 F)
50 C (122 F)
Wm
. Any sensor that